StomatologyEduJ 5(1) SEJ_5_1 | Page 42

ARE DENTAL MEASUREMENTS TAKEN ON PLASTER CASTS COMPARABLE TO THOSE TAKEN FROM CBCT IMAGES AND LASER SCANNED SURFACES? Table 1. Intra- and inter-operator repeatability (Bland-Altman analysis). Intraoperator Central incisor Interoperators First First First First Canine premolar molar premolar molar Hemiarch Central incisor Canine Vestibulopalatal/ Vestibulolingual Mesiodistal First First First First premolar molar premolar molar Vestibulopalatal/ Vestibulolingual Mesiodistal Left maxillary Calliper Bias 0.07 0.02 0.04 0.01 0.01 0.07 0.03 0.02 0.03 0.03 0.04 0.03 Reproducibility 96 95 95 99 95 97 98 99 97 99 98 95 Bias 0.03 0.13 0.14 0.05 0.00 0.23 0.04 0.06 0.20 0.16 0.16 0.21 Reproducibility 96 95 95 93 94 95 98 94 95 98 94 97 Bias 0.06 0.22 0.21 0.16 0.30 0.30 0.05 0.12 0.19 0.12 0.03 0.34 Reproducibility 91 87 83 87 78 78 91 90 94 80 75 72 Bias 0.02 0.00 0.04 0.06 0.03 0.04 0.05 0.03 0.06 0.05 0.04 0.07 Reproducibility 96 97 98 96 93 95 96 98 97 98 97 94 Bias 0.08 0.28 0.06 0.14 0.02 0.13 0.00 0.26 0.28 0.08 0.25 0.01 Reproducibility 98 88 93 96 90 81 97 94 89 94 94 89 Bias 0.10 0.06 0.04 0.20 0.04 0.21 0.10 0.25 0.24 0.04 0.09 0.10 Reproducibility 87 93 86 89 87 75 72 94 90 94 82 82 Digital CBCT Right mandibular Calliper Digital CBCT Bias values (absolute values) are in mm, reproducibility coefficients are in % Table 2. Bland-Altman analysis for the three measurement methods. Central incisor Canine Hemiarch First premolar First molar Mesiodistal First premolar First molar Vestibulopalatal/ Vestibulolingual Left maxillary Calliper - Digital Digital – CBCT Bias 0.00 0.02 -0.02 0.00 0.05 0.04 Reproducibility 100 100 99 100 99 99 Bias 0.05 0.00 -0.08 -0.02 0.02 -0.01 99 99 99 99 98 95 0.06 0.02 -0.10 -0.02 0.07 0.03 99 99 99 99 98 95 0.02 -0.01 0.03 -0.01 0.01 0.04 99 99 99 100 98 98 0.08 0.05 -0.03 -0.03 -0.02 0.02 97 98 98 99 91 97 Bias 0.10 0.04 0.00 -0.04 -0.01 0.06 Reproducibility 97 98 98 99 90 96 Reproducibility Calliper - CBCT Bias Reproducibility Right mandibular Calliper - Digital Bias Reproducibility Digital – CBCT Bias Reproducibility Calliper - CBCT Bias values (absolute values) are in mm, reproducibility coefficients are in % linear distances (crown dimensions) taken with three different techniques. Overall, differences among the measurements were limited, and their reproducibility very high, ranging between 90 and 100%. Together with the comparison among methods, we investigated the variability inherent to each measurement protocol, namely the effect of repeated measurements made by the same and different operators. We found limited 40 intra- and inter-operator variabilities. Indeed, the quantification of inter-operator reliability is necessary whenever multiple operators contribute to the analysis of the same dental reproductions. The good agreement between our two operators may be an effect of their prior calibration, which should be included in all measurement protocols [12]. Apparently, this is the first study that reported inter- Stoma Edu J. 2018;5(1): 38-42 http://www.stomaeduj.com