066_077ACConstellation
10/21/04
7:45 PM
Page 67
Vertical wall rebar prior to waterproofing.
Screen wall behind sedimentary wall displays vertical
reveal pattern at four feet o.c. to conceal plywood
form joints, snap tie layout within horizontal reveals.
67
Any embed placed in architectural concrete should
be radiused or rounded. However if square, rectangular, or objects with acute corners are placed, such
as the square light boxes mounted to our form, trim
bars should be added to outline each object to
minimize cracking.