Pro Installer November 2014 - Issue 20 | Page 17

17 PRO INSTALLER NOVEMBER 2014 PRO NEWS @proinstaller1 BFRC, SPACER BARS & MEASURED THERMAL CONDUCTIVITY VALUES The BFRC is the UK’s national system for rating Energy Efficient Windows and is responding to questions raised following its statement clarifying the situation regarding measured thermal conductivity values for spacer bars. Why has BFRC changed the way it deals with simulating spacer bars? BFRC has adapted its requirements to reflect the changes to BS EN ISO 10077-2 2012. This standard requires measured thermal conductivity values to be derived according to a very specific set of criteria. BFRC investigations have determined that the only way to currently satisfy the standard is to use a measured conductivity value obtained from Bundesverband-Flachglas (BF) 2 box model (currently this is the only item of data taken from the datasheet). Only datasheets currently available on the BF website (www. bundesverband-flachglas. de/shop/kostenfreie-downloads/bf-data-sheets-english) are deemed to be acceptable for new BFRC rating applications or for product substitutions. These changes came into place following numerous discussions with industry. Can BFRC license holders substitute components within a licensed window? Answer: BFRC license holders can change the components within a licensed window. However, as these changes are likely to have a substantial effect on the window’s energy rating performance, in most cases a full re-simulation and re-evaluation of the window in question is required. Under certain circumstances, it is possible to substitute certain components without requiring a re-simulation. Image courtesy of Thermoseal Group components does not result in a lowering of the window’s energy rating performance. It is important to bear in mind that simple substitution (without re-simulation) is only permissible for one component at a time. For instance, substituting a spacer bar of equal or ‘BFRC’s rules on substitution without re-simulation are designed to safeguard the homeowner’ The BFRC substitution rules, which were created in 2010 following consultation with the fenestration industry, are still applicable and available, and are designed to ensure that any simple substitution of better thermal performance is only permissible providing the type and depth of secondary sealant is unchanged. However, it is not possible to guarantee that the window’s energy rating will not decrease slightly. BFRC’s rules on substitution without re-simulation are designed to safeguard the homeowner in that the WER performance of a window will be the same (or slightly better) using these rules. Where the performance cannot be guaranteed to be the same or better, a full re-simulation and re-evaluation needs to take place. Clause 4 of the BFRC Substitution Rules for Glazed Units states that: “Spacer bars (including the primary sealant and desiccant) may be substituted when the replacement has an equal or lower effective thermal con- ductivity (measured to 3 decimal places) than the spacer bar specified in the original license. Effective thermal conductivity of the spacer bar (including the primary sealant and desiccant) shall be determined either by tabulated value from BS EN ISO 10077:2 2012 or if a measured value is required, thermal conductivity values shall be obtained from a currently listed 2 box model datasheet from the BF website.” (Web address as above) What depth of secondary seal is used for rating purposes? All spacer bars are simulating as being positioned with the top of the bar inset 12mm from the edge of the glass, as this is how the vast majority of IGU’s are manufactured in the UK. Deviation from this depth is permitted provided documentary evidence to support the compliant manufacture is supplied and is deemed to be acceptable by BFRC’s technical committee. BFRC is consulting with industry via the GGF Technical Committee which is currently reviewing the sealant depth issue. More information will be made available in due course. ‘BFRC is consulting with industry’ For further information contact BFRC direct by calling 020 7403 9200 or email [email protected]