Boilers & Maintenance
Babcock Wanson provides new boiler
house & plant for Stolthaven terminals
Babcock Wanson has designed a new thermal fl uid system to accommodate its
high effi ciency Thermal Fluid Heaters at Stolthaven Dagenham Ltd bulk liquid
terminal situated on the river Thames in Dagenham, Essex.
Babcock Wanson worked closely with Stolthaven Dagenham’s consultants
to provide the fi nal design of the boiler house and then install and fi t it out
with its EPC ES and TPC B Thermal Fluid Heaters. A large proportion of the
thermal design was also carried out by Babcock Wanson with the supply of
all the system valves and ancillary equipment to provide a complete system
with single point of responsibility. The system also incorporates a secondary
circuit to provide lower temperature thermal fl uid for the bitumen pump casing
heating. The project was a fast moving one with tight deadlines, all of which
Babcock Wanson met.
Tel: 020 8953 7111
CERTU
Unit 45
Tyburn
Birming
B24 8TG
www.babcock-wanson.co.uk
Gas Process Burners
24
PECM Issue 21
PECM716.indd 24
Lanemark gas burner systems offer users reliable, high effi ciency,
process heating solutions.
FD Series Packaged Oven/Dryer Burners
Specifi cally designed for process air heating applications in convection
ovens and dryers
High turndown/short fl ame lengths providing accurate process
temperature control
High effi ciency gas + air modulation, gas only modulation and simple
high/low control options
Heat Input Range: 9 kW – 1550 kW
D
D
D
D
FD-C high turndown oven/
FD-E low cost high turndown
dryer air heating burners.
oven/dryer air heating burners.
FD-GA modulating gas + air
process air heating burners.
TX Series Gas Fired Process Tank Heating Systems
High effi ciency (80%+) heating of all types of spray and dip process tanks
Compact high effi ciency small diameter immersion tube heat exchangers
occupying minimum tank space
Accurate performance modelling using Lanemark TxCalc design software
Heat Input Range: 15 kW (1½") – 1150 kW (8")
D
D
D
D
Midco HMA Series Air Replacement or “Make-Up” Air Heating Burners
Direct fi red, high effi ciency burner systems, for high volume air heating
applications such as paint spray booths, ovens and dryers.
Supplied either as Midco burner heads for OEM system integration or
as Lanemark DB or FDB complete packaged systems including modulating
gas valve trains and controls
Wide range of fi ring rates to suit alternative temperature rise and air
velocity system requirements
DbCalc system design software
D
D
D
Midco HMA high efficiency,
high turndown, air replacement
or “make-up” air heating burners.
TX high efficiency small diameter
D
immersion tube tank heating
systems.
CERTUSS (UK) Limited
Unit 45 Gravelly Ind Park
Tyburn
Road
Lanemark Combustion Engineering
Limited
Birmingham
Lanemark House, Whitacre Road, Nuneaton, Warwickshire CV11 6BW United
B24 Kingdom
8TG
Tel: +44 (0) 24 7635 2000 Fax: +44 (0) 24 7634 1166 E-mail: [email protected]
www.lanemark.com
24
PECM Issue 21
X4620 Lanemark Ad SDAW.indd 1
Tel : 0121 327 5362
Fax : 0121 328 2934
[email protected]
www.certuss.co.uk
COMBUSTION ENGINEERING
Issue 29 PECM
47
31/08/2016 09:04