but can also reduce the effective length of a cabling link or channel. Common causes of excessive return loss are plugs or jacks from vendors that aren’t compatible with each other, multiple connectors on a channel and poor contact between the cable conductor and contact of the connector (bad termination). The broadband debate... 35 these reasons, no major cable or connector manufacturer will accept test results from a qualifier for their cable certification or warranty programmes. Certifier or qualifier An installer can easily check whether a tester is a certifier or qualifier. A tester is considered a certifier if it meets ISO/ Beyond fault-finding IEC 61935 and TIA 1152-A accuracy requirements and has As well Not as finding faults in components the installation Level verified accuracy. Or, if down the tester measures a month goes by without or someone finding a new ETL way to III/IIIe send vast amounts of data a single fibre, but how will itself, certifiers determine the true broadband performance make of an installed PSNEXT, Loss, Insertion Loss and and ever-present high-speed a difference NEXT, to our Internet Return experience? We could be ACR-F, interconnected with experts from cabling system. Even where products appear to be labelled specifies a test frequency range of at least 500 MHz, then it’s all conceivable professions, accessing scientific and everyday equipment all over the globe, reaching communities of all shapes with a suitable rating, without field certification there’s no a certifier. and sizes, using all sorts of new applications and services — all in real time. High-speed broadband can enable our projects to way of knowing if the actual performance matches what has While certifiers are the best tool to guarantee installed be adopted across both our business and social lives, cabling and the only effective way to deliver this future is with a fibre optic-based been advertised. meets the stringent performance requirements infrastructure.Tech investment is hitting record highs in the UK and essential of this booming To ensure the components purchased provide the required defined by the the ISO/IEC and foundation ANSI/TIA standards bodies, growth is access to broadband. In an ideal world the whole of the United Kingdom’s telecoms network would be based off a pure fibre optic network, performance, installers should choose reputable brands. installers should remember that a cable certifier is only but in reality it makes more economic sense to upgrade what already exists. Convincing stakeholders However, premium brand components don’t completely an essential test tool on jobs where a certifier or cable that fibre is a necessary eliminate risk, so installations should be tested There with a is certifier manufacturer warranty to is help required. This is typically only the case for fibre. The good investment is yet another obstacle. a clear role here for providers demonstrate the business to prove they is meet case optic in 25% of jobs. The rest of to the time, a but cable network news that the all performance of the major standard. operators are bringing fibre cables ever closer homes, we and need to focus on take-up of transmission tester can be used to create superfast broadband by businesses, not just consumers. In ten or twenty years we might be comprehensive able to replace the last few metres of Why not qualify? proof of performance reports to industry recognised copper and coax with a true fibre optic connection, but time will tell. Unlike rigidly standardised certification, cable qualification standards. has no Enjoy defined the tests or performance and accuracy Certifiers are extremely important for finding faulty issue. specifications in the standards organisations. The components and sources of installation mistakes, as well as manufacturer of the LAN qualifier simply decides what to test, helping to ensure that the materials are genuine, high-quality Nick Wells how accurate the instrument is and how to report the results. products and meeting customer requirements for warranties. This means from one brand of qualifier can’t be However, installers should always carefully match their choice Editor the – results Netcomms Europe compared to another. Plus, without a definition for pass/fail of tester to the needs of the job to ensure efficient and limits, what does it mean when a qualifier fails a cable? For profitable operations. n INTELLIGENT R&MinteliPhy – Automated Infrastructure Management by R&M Manually managed infrastructure data has a 10% error rate*, 20-40% of ports in a network are forgotten over time**. The automated R&MinteliPhy solution continuously monitors each connection in one or more data centres or local networks, a (remote) central server records cabling status. The AIM-based solution has functions for management, analysis as well as planning cabling and network cabinets. R&MinteliPhy is easy to retrofit and can halve network monitoring and management costs. When new devices are integrated or changes made updates are automatically generated. Unused patch panels and ports in active equipment are instantly detected. Data can be traced in real time with a PC or smartphone, faulty connections are located in seconds. More info: [email protected] Convincing cabling solutions * Source: Watson & Fulton ** Source: Frost & Sullivan www.netcommseurope.com www.networkseuropemagazine.com NETCOMMS europe Volume V Issue 3 2015