Lehmann Rotary Tables Publications Main catalog (PGD inside!) | Page 34

Indexing accuracy / Attainable workpiece accuracies Measuring and recording the angular accuracy, important application information Fully automated measuring system for indexing accuracy measurement Elasticity of tilting axes (reference values for pitch error) EA + M Overview Measuring method used to determine the gear unit's accuracy to VDI/DGQ 3441 or ISO 230-2 T1 TF –m  easured at operating temperature of the unit after 5 warm-up cycles – 5 measuring cycles – 24 measuring points (15° steps) – Acceleration 500°/s2 – All measured values apply in the unloaded condition at an ambient temperature of approx. 22°C T2 / T3 fix(X) -12 vario(X) -44 fix(X) 36 vario(X) -20 TF-510510/511510 -22 -90 44 -60 TF...T1-510520/511520 -8 -30 40 -6 TF...T1-520520 T2-507510 -15 -25 -65 – 76 -35 -16 – T2-510520/511520 -15 – 45 – T3-507510 -38 – 29 – T3-510520/511520 -23 – 45 – Recommendation: In orde