e-Showcase Sungrow PV Grid-Connected Inverters 2015~2016 | Page 33

String Inverter Input Side Data Max. PV input power Max. PV input voltage Startup voltage Stop Voltage MPP voltage range MPP voltage range for nominal power String Fuse No. of MPPTs Max. number of PV strings per MPPT Max. PV input current Maximum DC short circuit current Max. current for input connector Max. Cable Size Arc Flash Detection DC Switch Insulation Detection DC Surge Arrestor 67500W 1000V 300V 280V 300~950V 550~850V / 513~850V Positive and Negative 4 4 112A (28A/28A/28A/28A) 200A 12A 10AWG, Cu or Al Yes Yes Yes Type II DIN rail surge arreste Output Side Data Nominal AC output power Max AC output power (PF=1) Max. AC output apparent power Max. AC output current Nominal AC voltage AC voltage range Nominal grid frequency Grid frequency range THD DC current injection Power factor Max. Cable Size AC Surge Arrestor 60000W / 56000W 66000W 66000VA 80A 3Ǿ/3W +Ground, 480Vac 422~528Vac  60Hz 55~65Hz <3% (Nominal power) <0.5%In >0.99@default value at nominal power, (adj. 0.8 eading ~ 0.8 lagging) 0AWG, Cu or Al Type II DIN rail surge arreste (40kA) Protection Mechanical Data Anti-islanding protection Low Voltage Ride Through DC reverse connection protection AC short circuit protection Leakage current protection Overvoltage protection AC switch Dimensions (W*H*D) Yes Mounting method Yes Weight Yes Yes Yes Type II DIN rail surge arrester Yes System Data 665*915*276 mm Wall bracket 70kg 26.2*36*10.9inch 154lbs Communication Max. efficiency CEC efficiency Isolation method Ingress protection rating Tare Loss Operating ambient temperature range Allowable relative humidity range Cooling method Max. operating altitude Display Communication DC connection type AC connection type Certification Safety and EMC Standard 98.90% Standard RS485 98.60% Standard Ethernet Transformerless Standard I/O dry contact NEMA4X Modbus Protocol <1W -25~60℃ (>50℃ derating) -13…+140℉ (>122℉ derating) 0~100% Smart forced air cooling 4000m (>3000m derated) 13,000ft (>9,800ft derated) Graphic LCD RS485 / Ethernet Screw terminals Screw clamp terminal cCSAus UL 1741, IEEE 1547, IEEE1547.1, CSA C22.2 107.1-01-2001, FCC Part 15 Sub-part B Class B Limits Circuit Diagram MPPT1 (Boost) MPPT2 (Boost) DC EMC Filter Inverter Circuit Relay AC Switch L1 L2 L3 N AC EMC Filter AC Reactor MPPT3 (Boost) DC EMC Filter DC Bus MPPT4 (Boost) DC FUSE PE To Grid DC EMC Filter DC3 In DC EMC Filter DC4 In DC1 In DC Switch DC2 In CURRENT READING AC SPD DC SPD Fans Auxiliary Power Circuit DSP+CPLD LCD/RS485 31