Central Inverter Input (DC) Max. PV input voltage Max. PV input current MPP voltage range No. of DC inputs PV array configuration 1000V 2000A 550~850V 1, 8-14 Negative ground (standard), floating or positive ground (opional) Output (AC) 1000kW 1100kVA 1650A <3 % (Nominal power) 385V 338~424V 50Hz/60Hz 47~52Hz/57~ 63Hz 0.8 overexcited ~0.8 underexcited No <0.5 % In Nominal AC output power Max. AC output apparent power Max. AC output current THD Nominal AC voltage AC voltage range Nominal grid frequency Grid frequency range Power factor Isolated transformer DC current injection Efficiency Max. efficiency European efficiency CEC efficiency 98.80% 98.40% 98.50% Protection Input side disconnection device Output side disconnection device DC overvoltage protection AC overvoltage protection Grid monitoring Ground fault monitoring Over temperature protection Insulation monitoring DC load switch; Breaker (Optional) Breaker Yes Yes Yes Optional Yes Optional General Data Dimensions (W*H*D) Weight Operating ambient temperature range Night power consumption External auxiliary supply voltage Cooling method Ingress protection rating Allowable relative humidity range Max. operating altitude Fresh air consumption Display Communication 2598*2164*1000mm 2050kg -30~+60℃ (>55℃ derating) <20W 400/480V (3/N/PE) Temperature controlled air-cooling NEMA 3R (IP54) 0~95%, no condensing 4000m (>2000m derating) 4425m³/h LCD RS485/Modbus, Ethernet Circuit Diagram Power Module DC+ AC Contactor DC Switch AC Breaker L1 DC EMC Filter DC- DC SPD PE AC Filter AC EMC Filter L2 L3 AC SPD PE 17