e-mosty December 2018 e-mosty December 2018 | Page 60

VII. CABLES Adjustable sockets are used on the main span and an adjuster block made from 80mm steel plate in combination with 32mm threaded bar is used at the anchorage. All of the cable attachment points have been designed with an additional 50 diameter hole to accommodate the stressing equipment. The bridge uses 1x37 1620MPa spiral strand cables sourced from Germany. For the main span 20mm cables are adopted, and for the back-spans 25mm are used. There are 6 sets of cables for the main span (12 total) and 3 sets for the back-span (6 total). Corrosion protection of the cables is achieved by the adoption of a minimum 250g/m2 coating of 95% zinc + 5% aluminium to all strands making up the strand. Cables are designed as per the Post Tensioning Institute (PTI) Recommendations for Stay-Cable Design, Installation and Testing, 6th edition 2012. Figures 14 and 15 ←: Spiral strand stay cable detail Back-span cables being stressed Figures 16 – 18 ↙ ↓: Completed Bridge 4/2018