Dobbins JLUS IMP Public Draft Light Pollution Study | Page 52

    Measuring Light Output Light output is measured in various ways. To understand lighting in the  current lighting regulations for each jurisdiction, a brief explanation of how  light output can be measured is provided as follows.  Footcandle  Footcandle is an illuminance that equals one lumen  per square foot.  One footcandle is equal to  approximately 10 lux (one lumen per square meter).  Lumens  Lumens is the unit of measurement used to quantify  the amount of light, or brightness, produced by a  light source.  Wattage  Wattage measures the amount of energy a bulb  uses.     Lighting Regulations by Jurisdiction Cobb County The Cobb County Zoning Ordinance, Section 134‐275.1 identifies regulations  for the Military Airport Hazard District for the purpose of establishing and  contributing to the safe operations at Dobbins ARB, to facilitate orderly  development around the airfield, to protect property values, and to control  and minimize noise and potential accident impacts on the surrounding areas  of Cobb County and the City of Marietta.   As part of this ordinance, in  Section 134‐275‐1.4.4, the Military Airport Hazard District restricts any use  that would make it difficult for pilots to distinguish between airfield lights  and other lights, or that result in glare in the eyes of the pilots using the  airfield or impair the visibility of the airfield.  While this supports pilot  visibility, the section is unclear on how this would be accomplished,  particularly for permitted uses.  Page 5‐2  For areas outside of the Military Airport Hazard District, and those inside  subject to Section 134‐275‐1.4.4, outdoor lighting is regulated through  lighting plans approved by the County Department of Transportation.  The  lighting criteria for the plans are outlined in Section 134‐269.  Information  provided must include the location of all proposed lights and nearby County  roads and adjacent properties as well as the arrangement of all poles; height  of poles; number of luminaries per pole; mounting heights of luminaries;  wattage of proposed lights; mounting angle of luminaires; and lamp source  to be used.  There are no provisions in the County Code permitting or  restricting temporary outdoor lighting or upward‐directional lighting in any  zoning district.  Sign regulations are included in the Zoning Ordinance.  Electronic signs are  defined as a sign that is operated by computer controller, microprocessor  controller, or remote control and uses LED, liquid‐crystal display (LCD),  plasma, or like panels or screen. Per the ordinance, these types of signs are  restricted to nonresidential areas and to a brightness of no more  0.20 footcandles above ambient light as measured at a distance of 125 feet.  The only other restriction for brightness is that electronic signs may not  operate at brightness levels of more than 0.1 footcandles (the illuminance  equaling one lumen per square foot) above ambient light levels if within the  line‐of‐sight of a residentially occupied structure.  City of Marietta The City of Marietta Zoning Ordinance includes an Air Installation  Compatible Use Zone (AICUZ) Overlay District in Section 712.05.  The intent  of this district is to contribute to the safe operations of Dobbins ARB,  facilitate orderly development around the airfield, protect property values,  and to control and minimize noise and potential accident impact  surrounding the City of Marietta.  Pursuant to Section 712.05.B.6.c,  development is restricted in any portion of the Overlay District if it will  “produce light emissions, which would either directly or indirectly  DRAFT Dobbins Air Reserve Base Light Pollution Study  March 2018