Dobbins JLUS IMP Public Draft Light Pollution Study | Page 262
MODEL LIGHTING ORDINANCE - USER’S GUIDE
MODEL LIGHTING ORDINANCE - TEXT
V. RESIDENTIAL LIGHTING - User’s Guide
Property Type: Residential
Lighting Zone 1
Luminaire
Type
Maximum
Initial
All owed Initial
Luminiare Luminaire Lumens
Lumens*
(Table G)
Luminaire
Full y
Lamp
Description
Shielded
Type
Controls Compliant
Decorative w all
A
Front Entry
sconce
No
9W CFL
420
420
None
Yes
Fully shielded
Occupancy
B
Garage Do or
w all pack
Yes
23W CFL
1050
1260
Sensor
Yes
Decorative w all
Occupancy
C
Back Entry
sconce
No
7W CFL
280
315
Sensor
Yes
Fully shielded
Occupancy
D
Shed Entry
w all pack
Yes
40W INC
343
1260
Sensor
Yes
Fully shielded
E
Driveway
post top
Yes
13W CFL
1260
1260
None
Yes
*Initi al Luminaire Lumens are calculated by multiplying the total in itial lamp lumens by the luminaire efficiency.
If the luminaire efficie ncy is not known , assume an efficiency of 70% and multiply the lamp lum en value by 0.7.