With the SCT current transformers, Beckhoff completes the energy
measurement chain from recording the physical measured value
to data transmission in the cloud. The portfolio of the new current transformers
covers all relevant applications: for currents from 1 to 5,000 A
and with versions as ring-type current transformers for new installations
or split-core current transformers for flexible retrofitting.
The SCT current transformers offer the possibility of implementing
reliable power sensors directly in the field as an integral component of
PC-based control technology. Two concepts can be selected, each highly
scalable via different designs and performance classes and therefore suitable
for a wide variety of applications. The SCT series is extremely diverse,
ranging from cost-effective 3-phase transformer sets for building technology
to standard industrial transformers for mechanical engineering and
solutions for test benches with particularly high accuracy requirements.
www.beckhoff.com/SCTxxxx
News | I/O
ELM2742, ELM2744 | Multiplexer, 1 x 4 solid-state relays
48 V AC/DC, 1 A, potential-free make contact
With the ELM274x terminals several sensors or sources can now be
connected at the same time to one analog input channel. To this end,
the ELM2742 and ELM2744 are equipped with non-wearing solid-state
relays (semiconductor switches) as switching elements, which are specially
designed for small analog signals. The multi-channel recording of
analog signals as well as the flexible switching of various test states is
thus simple to achieve without externally connected switches.
www.beckhoff.com/ELM2742
www.beckhoff.com/ELM2744
EP6090 | Display box with navigation switch and
operating hours counter
The EP6090 display box has an illuminated, low-reflection LC display
that displays variable machine data such as status and diagnostic
information directly on the box. The two-line display with 16 characters
each is freely programmable and automatically switches to scrolling
text mode if required.
• display of defined special characters
• resettable time measurement/counter
• non-resettable operating hours counter
• manual/automatic storage intervals
www.beckhoff.com/EP6090
We reserve the right to make technical changes.
9