Metals in seawater
Parameter
LOQ (µg/l)
Parameter
LOQ (µg/l)
Parameter
LOQ (µg/l)
Al 0.7 Fe 4 Ni 0.5
Ba 0.1 Hg 0.002 P 40
Ca 200 K 500 Pb 0.3
Cd* 0.05 Mg 90 S 160
Co 0.05 Mn 0.1 Si 200
Cr 0.1 Mo 0.1 Sr 50
Cu 0.5 Na 120 Zn 2
*A higher LOQ applies to samples with high molybdenum levels.
Minimum sample volume:
60 ml
Method:
ICP-OES, ICP-SFMS and AFS
Maximum salinity:
3.5%
Note:
LOQs apply to routine analyses. Lower LOQs can be achieved by specially
optimized analyses.
Metals in brackish water
Parameter
LOQ (µg/l)
Parameter
LOQ (µg/l)
Parameter
LOQ (µg/l)
Al 0.3 Fe 2 Ni 0.2
Ba 0.04 Hg 0.002 P 5
Ca 200 K 500 Pb 0.1
Cd* 0.02 Mg 90 S 160
Co 0.02 Mn 0.04 Si 40
Cr 0.04 Mo 0.04 Sr 10
Cu 0.2 Na 120 Zn 0.8
*A higher LOQ applies to samples with high molybdenum levels.
Minimum sample volume:
60 ml
Method:
ICP-OES, ICP-SFMS and AFS
Maximum salinity:
1.2%
Note:
LOQs apply to routine analyses. Lower LOQs can be achieved by specially
optimized analyses.
Low level dissolved metals (freshwater)
Parameter
LOQ (µg/l)
Parameter
LOQ (µg/l)
Parameter
LOQ (µg/l)
Al 0.2 Fe 0.4 P 1
As* 0.05 Hg 0.002 Pb 0.01
Ba 0.01 K 400 S 160
Ca 100 Mg 90 Si 30
Cd** 0.002 Mn 0.03 Sr 2
Co 0.005 Mo 0.05 Zn 0.2
Cr 0.01 Na 100 Cu 0.1 Ni 0.05
*A higher LOQ applies to samples with high chloride levels.
**A higher LOQ applies to samples with high molybdenum levels.
Minimum sample volume:
60 ml
Method:
ICP-OES, ICP-SFMS and AFS
TOTAL METALS ARE ALSO
AVAILABLE. CONTACT US
FOR MORE INFORMATION.
10
Product catalogue Water
RIGHT SOLUTIONS • RIGHT PARTNER