ALS Product catalogues AIR | Page 20
ASH
Incinerator Residue Monitoring parameters
LOQ
(µg/sample) Minimum sample
amount
0.1 % plastic, 10 g
TOC (total organic carbon) 100 mg/kg dw glass, 50 g
TC (total carbon) 100 mg/kg dw glass, 50 g
Parameter
dry matter
total soluble fraction
0.5 % plastic, 50 g
40 mg/kg dw plastic, 20 g
300 mg/kg DW plastic, 50 g
sulfate 0.1 % DW plastic, 50 g
sulfur (total) 0.1 % DW plastic, 50 g
chloride
fluorine, total
heavy metals See separate tables
PCDD/F See separate table
coplanar PCBs See separate table
polycyclic aromatic hydrocarbons (PAH) See separate table
Waste classification criteria for ash landfill
Waste acceptance criteria (WAC) - non-hazardous waste (water leaching)
Limit value (mg/l)
Parameter
ALS LOQ
(mg/l)
Single step
(L/S=10) Two stage*
(L/S=2, L/S=8) Percolation test
(usually L/S=0.1) As 0.2 0.2 0.3 0.05
Ba 10 15 20 0.003
Cd 0.1 0.3 0.3 0.005
Cr total 1 2 2.5 0.001
Cu 5 12.5 30 0.01
Hg 0.02 0.025 0.03 0.001
Mo 1 2.5 3.5 0.02
Ni 1 2.5 3 0.02
Pb 1 2.5 3 0.05
Sb 0.07 0.1 0.15 0.05
Se 0.05 0.15 0.2 0.025
Zn 5 12.5 15 0.01
chloride 1500 5000 8500 1
fluoride 15 30 40 0.2
sulphate 2000 5000 7000 5
DOC 80 190 250 0.5
TDS 6000 20000 - 10
pH >6 >6 - 1
* Value mentioned for L/S=2 L/kg.
Minimum sample amount:
0.5 kg dry waste
Waste acceptance criteria (WAC) - non-hazardous waste (dry matter)
Parameter
LOQ Sample amount Limit value
0.01% DW glass, 50 g 5%
0.05 mmol/l plastic, 200 ml -
TOC*(coulometry)
ANC**
(potentiometric titration)
* Total dissolved carbon
** Acid neutralization capacity at pH 4.5
20
Product catalogue Air/emission
RIGHT SOLUTIONS • RIGHT PARTNER