■■ Safety options -- Soft starter of the supply and/or return centrifugal fan which prolongs the set time mainly aimed at installations with cloth ducts. Compulsory for motors with an output of 15 kW and above. -- Differential pressostat for the detection of clogged filters. -- Differential pressostat for control of air flow. -- Smoke detecting station in accordance with the NF S 61-961 standard. -- Refrigerant leak detector. This allows prompt identification of gas leaks, guaranteeing the safety of any people in the vicinity. Installation of the device ensures compliance with European standards F-GAS and EN378 as well as ASHRAE 15. ■■ Packing options -- Maritime packing SEI4C (with or without gas burner). -- Skis for transporting in closed container (except with assemblies MC1 and MRC1). ■■ Service options -- Commissioning and extension of guarantee of 1 year (with or without gas burner) in pieces, workforce and displacement. -- Commissioning and extension of guarantee of 2 years (with or without gas burner) in pieces, workforce and displacement. ■■ Electric panel options -- Electrical power supply with neutral. -- Numeration of components in the electrical panel. -- Numeration of w ired. -- Energy meter for monitoring of the power consumption of the installation. ■■ Control / communication options -- TCO user terminal, for installation on the electric panel, instead of pGD1 terminal. -- Kit remote control to 200 meters with pGD1 terminal (pGD1 terminal + 2 TCONN bypass cards). In this case it´s posible to install the TCO terminal on the electric panel. 200 m -- Change to CARRIERrtc medium electronic control with TCO terminal as standard and pGD1 terminal as optional (available for models 415 to 720): this control does not manage cooling recovery circuit, passive recovery or gas burner. -- Communication CARRIERrtc & CARRIERrtc medium controls allow the connection to a centralised technical management system by using a specific BMS card for some of the following communication protocols: --RS485 serial cards for network communication with protocols: Carel, Modbus, LonWorks®, BACnetTM MSTP, Konnex. --Ethernet pCO Web card for network communication with protocols: Modbus TCP/IP, BACnetTM Ethernet, TCP/IP, SNMP V1-2-3, FTP and HTTP. ■■ Supervision solutions Different solutions of supervision are available according to the dimensions of the installation. -- pCO Web It is the solution for the management and supervision of a single unit if it incorporates the Ethernet pCO Web card. -- PlantWatchPRO It is a solution designed for the monitoring of installations of medium - small dimensions, with ability to manage up to 10 units. Suitable for technical environments, it has no parts in movement. Includes: 5.7 “ touch display, buzzer for notifications and 2 USB ports for downloading reports, charge devices models and applying service packs. In this case, each unit needs one RS485 Carel / Modbus board. -- PlantVisorPRO2 This is the solution for the management and supervision of air-conditioning installations with up to 300 units. It performs advanced monitoring and maintenance functions and enables creating areas and groups which simplify the management of the installation. It also allows the integration of energy meters for monitoring the power consumption of the installation. PlantVisorPRO2 is available in two versions: • Box: comprised of the CPU unit and, optionally, by monitor and keyboard. • Touch: this includes the CPU and the touchscreen in the one device. In this case, each unit needs one RS485 Carel / Modbus board. Software for remote center management TCONN TCONN HTTPS Terminal pGD1 µPC MEDIUM -- Relative humidity probes of return and outdoor air: compulsory in units with enthalpic or thermoenthalpic free-cooling. -- Ambient air temperature probe: If the unit needs the relative humidity of the outdoor air probe (optional), this probe can’t be installed on the board (standard), it must be connected to the Field-bus. -- Ambient air enthalpy probe: compulsory in units with gas burner + enthalpic or thermoenthalpic free-cooling. C A R R I E PlantWatchPRO (10 units) R 2 0 1 6 / 2 0 1 7 PlantVisorPRO2 (300 units) These systems allow the installation in remote management. Through a single connection to the Internet is accessed the information system. The Web interface, which is available for the local user, allows the monitoring and the complete configuration of the installation: from the office or any other user’s current location. For remote control of multiple sites, there are dedicated tools for centralized management as RemotePRO and RemoteValue. 833 CONTROLS RJ12 0,8 m S90CONN002 pCO Web (1 unit) AIR TREATMENT PACKAGED ROOFTOP UNITS  50EN/EH 415-1200