AHI Carrier Catalog | Page 828

Physical Data (EN-14511-2011) 50EN/EH Cooling Cooling capacity * Power input *** EER performance Heating Heating capacity ** Power input *** COP performance Outdoor circuit fan Nominal air flow Available static pressure Type Number Diameter Output AIR TREATMENT Speed Indoor circuit supply fan Nominal air flow Available static pressure Type Number / no. turbines Motor output Power input Speed Compressor Type Number of compressors Number of stages Number of circuits Oil type Volume of oil Electrical characteristics Electrical power supply Power supply Maximum absorbed current Compressor(s) Outdoor fan(s) Indoor fan Control Total Refrigerant Type Global warming potential (GWP) **** Charge Environment impact Dimensions Length Width Height Weight Condensate outlet Ø * ** *** **** 650 720 840 960 1100 1200 kW kW 152,1 48,2 3,2 168,7 55,6 3,0 199,9 66,1 3,0 218,9 75,6 2,9 257,5 88,2 2,9 280,8 99,9 2,8 kW kW 158,9 43,8 3,6 177,1 50,0 3,5 207,7 60,0 3,5 230,1 67,0 3,4 267,6 81,9 3,3 293,1 91,1 3,2 55.000 56.000 m3/h mm.w.c 4 Axial 4 mm 2 x 630 + 2 x 800 kW 2 x 0,7 / 0,4 + 2 x 2,0 / 1,3 r.p.m. 875 / 650 895 / 685 75.000 75.000 112.500 112.500 27.500 m3/h mm.w.c 17,5 Centrifugal mm 2/2 kW 2x4 kW 5,15 r.p.m. 654 30.000 17,5 33.000 17,5 37.000 17,5 42.000 17,5 46.000 17,5 2x4 6,21 677 3/3 3x3 5,87 677 3x3 7,49 714 1/3 18,5 13,47 873 22 16,62 916 l 4 x 800 4 x 2,0 / 1,3 6 6 x 800 6 x 2,0 / 1,3 895 / 685 895 / 685 Scroll 4 4 2 4 Copeland 3MAF 32cST, Danfoss POE 160SZ, ICI Emkarate RL 32CF, Mobil EAL Artic 22CC 4 x 3,3 4 x 6,2 4 x 6,2 4 x 6,2 4 x 6,2 4 x 6,2 400 V / III ph / 50 Hz (±10%) 3 Wires + Ground A A A A A 100,4 11,2 18,0 1,8 131,4 R-410A 2.088 kg 35,0 tCO2eq 73,1 mm mm mm kg 122,0 11,2 18,0 1,8 153,0 140,6 17,2 20,7 1,8 180,3 159,2 17,2 20,7 1,8 198,9 182,2 25,8 37,0 1,8 246,8 205,2 25,8 42,0 1,8 274,8 41,0 85,6 44,0 91,9 46,0 96,0 57,0 119,0 58,0 121,1 2.374 6.316 2.205 2.095 3.022 3.135 4.816 2.205 2.095 2.093 2.152 1 1/4” adaptor 2.277 Cooling capacity calculated in accordance with the EN-14511-2011 standard given for indoor temperature conditions 27ºC, (19ºC WB) and 35ºC outdoor temperature. Heating capacity calculated in accordance with the EN-14511-2011 standard given for indoor temperature conditions 20ºC and 6ºC WB outdoor temperature. Total power input by compressors and motorised fans under nominal conditions, calculated in accordance with the EN-14511-2011 standard. Climatic warming potential of a kilogram of fluorinated greenhouse gas in relation to a kilogram of carbon dioxide over a period of 100 years.. 828 C A R R I E R 2 0 1 6 / 2 0 1 7