SPLIT-SYSTEM UNITS 38NZ/NF & 40NZ/NF
Optional
Optional for the indoor unit 40NZ/NF
■■ Outdoor environment
■■ Safety
Temperature
-- Thermal and acoustic insulation of the casing 30 mm
thick, with reaction to fire Euroclass A2-s1, d0.
-- Soft starter of the supply and/or return centrifugal
fans which prolongs the set time mainly aimed at
installations with cloth ducts.
Corrosion
-- Coil with copper pipes and copper fins.
-- Differential pressostat for the detection of clogged
filters.
-- INERA® coil with copper pipes and fins of an
aluminium alloy, of high performance and great
resistance to the corrosion (indoor unit and/or hot
water coil).
-- Coil with copper pipes and aluminium fins with
polyurethane and Blygold® coating (indoor unit and/or
hot water coil).
-- Condensates drain pan in stainless steel.
■■ Comfort / heating options
-- Differential pressostat for control of air flow.
-- Smoke detecting station in accordance with the NF S
61-961 standard.
-- Refrigerant leak detector (with CARRIERrtc control).
This allows prompt identification of gas leaks,
guaranteeing the safety of any people in the vicinity.
Installation of the device ensures compliance with
European standards F-GAS and EN378 as well as
ASHRAE 15.
-- Hot water auxiliary coil, with three-way valve, for
heating in heat pump units.
■■ Comfort / indoor air quality options
-- Filtration of the supply air:
• Gravimetric filter G4.
• Gravimetric filter G4 + creased opacimetric filters F6 to F9.
• Double stage of creased opacimetric filters:
F6 + F7, F6 + F8 ó F7 + F9.
-- Air quality probe for installation in the environment
or in duct to enable measuring CO2 and/or volatile
compounds (with CARRIERrtc control).
C
A
R
R
I
E
R
2
0
1
6
/
2
0
1
7
■■ Installation
-- Antivibration mounts made of rubber.
-- Compatibility 2 x 1: two indoor units: 40NZ/NF and
one outdoor unit: 38NZ/NF (models 200 to 360).
• Two indoor units can be operated:
* simultaneously, with a single control and a single
terminal.
* separately, each unit with its control and its own
terminal.
* two indoor units can be operated separately, each
unit with its control board but with a single terminal
(only with CARRIERrtc control and pLAN network).
• The option of simultaneous operation is not possible
for indoor units with supply plug-fan or mixing box.
Compatibility 2 x 1
Models
Outdoor unit: 38NZ/NF
200
240
320
360
Indoor unit: 40NZ/NF
2 x 100
2 x 120
2 x 160
2 x 180
-- C
entrifugal supply fan with high available pressure,
from 7 to 60 mm.w.c.
-- Electronic plug-fan(s) in air supply and/or return
(please consult optional for “Energy saving/recovery”).
-- Position of supply and/or return of the indoor circuit
air: side or upper.
-- Supply plenum with punched or double deflection
grille, which allows air to be discharged through either
side.
Note: Upper suply of the 40NZ/NF unit is mandatory
with this plenum.
803
CONTROLS
-- Auxiliary electrical heaters. With this option, the air
flow controller is included.
AIR TREATMENT
If the unit includes hot water coil and free-cooling, and
works with negative temperatures of outdoor air, an
anti-freeze thermostat as safety system is mandatory.