AHI Carrier Catalog | Page 803

SPLIT-SYSTEM UNITS  38NZ/NF & 40NZ/NF Optional Optional for the indoor unit 40NZ/NF ■■ Outdoor environment ■■ Safety Temperature -- Thermal and acoustic insulation of the casing 30 mm thick, with reaction to fire Euroclass A2-s1, d0. -- Soft starter of the supply and/or return centrifugal fans which prolongs the set time mainly aimed at installations with cloth ducts. Corrosion -- Coil with copper pipes and copper fins. -- Differential pressostat for the detection of clogged filters. -- INERA® coil with copper pipes and fins of an aluminium alloy, of high performance and great resistance to the corrosion (indoor unit and/or hot water coil). -- Coil with copper pipes and aluminium fins with polyurethane and Blygold® coating (indoor unit and/or hot water coil). -- Condensates drain pan in stainless steel. ■■ Comfort / heating options -- Differential pressostat for control of air flow. -- Smoke detecting station in accordance with the NF S 61-961 standard. -- Refrigerant leak detector (with CARRIERrtc control). This allows prompt identification of gas leaks, guaranteeing the safety of any people in the vicinity. Installation of the device ensures compliance with European standards F-GAS and EN378 as well as ASHRAE 15. -- Hot water auxiliary coil, with three-way valve, for heating in heat pump units. ■■ Comfort / indoor air quality options -- Filtration of the supply air: • Gravimetric filter G4. • Gravimetric filter G4 + creased opacimetric filters F6 to F9. • Double stage of creased opacimetric filters: F6 + F7, F6 + F8 ó F7 + F9. -- Air quality probe for installation in the environment or in duct to enable measuring CO2 and/or volatile compounds (with CARRIERrtc control). C A R R I E R 2 0 1 6 / 2 0 1 7 ■■ Installation -- Antivibration mounts made of rubber. -- Compatibility 2 x 1: two indoor units: 40NZ/NF and one outdoor unit: 38NZ/NF (models 200 to 360). • Two indoor units can be operated: * simultaneously, with a single control and a single terminal. * separately, each unit with its control and its own terminal. * two indoor units can be operated separately, each unit with its control board but with a single terminal (only with CARRIERrtc control and pLAN network). • The option of simultaneous operation is not possible for indoor units with supply plug-fan or mixing box. Compatibility 2 x 1 Models Outdoor unit: 38NZ/NF 200 240 320 360 Indoor unit: 40NZ/NF 2 x 100 2 x 120 2 x 160 2 x 180 -- C entrifugal supply fan with high available pressure, from 7 to 60 mm.w.c. -- Electronic plug-fan(s) in air supply and/or return (please consult optional for “Energy saving/recovery”). -- Position of supply and/or return of the indoor circuit air: side or upper. -- Supply plenum with punched or double deflection grille, which allows air to be discharged through either side. Note: Upper suply of the 40NZ/NF unit is mandatory with this plenum. 803 CONTROLS -- Auxiliary electrical heaters. With this option, the air flow controller is included. AIR TREATMENT If the unit includes hot water coil and free-cooling, and works with negative temperatures of outdoor air, an anti-freeze thermostat as safety system is mandatory.