AHI Carrier Catalog | Page 675

INDIVIDUAL COMFORT MODULES  42BJ Important: If the ICM is fitted with a return air temperature sensor, the constant fresh air flow rate must not exceed 50% of the air flow rate delivered by the unit at minimum speed. The technology ensures totally safe self-regulation of the dissipated power. In addition, each electric heater is fitted with a self-resetting safety thermostat of the normally closed type that cuts out when the temperature rises to 70°C with an average differential of 20 K. Note: The 16.6 l/s or 60 m3/h fresh air controller can be modified on site by removing or retracting of the two plastic restrictions in order to bring its capacity up to a maximum constant fresh air flow of 44.4 l/s (160 m3/h). Caution: It is vital to disconnect the ICM from the general power supply before carrying out any work on the electric heater. A label attached to the 42BJ shows how to modify the co ntrol of the two plastic restrictions. Note: To operate correctly, the 8.3 l/s (30 m3/h) constant fresh air flow controller requires a differential pressure in the range 50 Pa to 200 Pa. The 16.6 l/s (60 m3/h) constant fresh air controller requires a differential pressure in the range 70 Pa to 200 Pa. ■■ PTC electric heater (option) These are high-performance PTC electric heaters (PTC = positive temperature coefficient) which make use of two technologies: electric heating and surface temperature limitation (a state-of-the-art technology based on the use of ceramics). Enhanced comfort without stratification: supply air temperature = 35°C The true dissipated power is then dependent on the temperature and flow rate of the incoming air. Technical specifications Water valve pressure drop AIR TREATMENT 2 1 Pressure drop, kPa 1 2 Kvs = 1 Kvs = 1.6 CONTROLS It should be noted that the valve body is the same for whatever controller option is chosen. ■■ Electrothermal actuator The actuator is a 230 V a.c. on/off type. Linear movement is provided by the expansion and contraction of a wax element heated by an electrical resistor. ■■ Two-way 1/2” valve body -- 1/2” male BSP connection for union nuts -- Straight valve body with arrow indicating direction of flow embossed on valve body -- Nominal size DN 15 for 1/2” valve -- Fluid: water and glycol solution (max. 40% glycol) -- Operating range: 2-90°C -- Nominal pressure: PN 16 bar (1600 kPa) -- Kvs = 1.6 ■■ Three-way 1/2” valve body (with integral bypass) -- 1/2” male BSP connection for union nuts -- Straight valve body with arrow indicating direction of flow embossed on valve body -- Nominal size DN 15 for 1/2” valve -- Fluid: water and glycol solution (max. 40% glycol) -- Operating range: 2-90°C -- Nominal pressure: PN 16 bar (1600 kPa) -- Kvs = 1 Water flow rate, l/s (l/h) Valves (option) C A R R I E R 2 0 1 6 / 2 0 1 7 675