AHI Carrier Catalog | Page 644

Physical and electrical data at Eurovent conditions 42NL - Size 5 With G1 filter - without plenum 42NL 529 Fan speed 2V (Eurovent certification speeds) (L) Air flow l/s 82 m3/h 539 5V 6V (M) (H) 141 172 188 231 255 82 295 508 618 675 831 918 Pa 0 0 0 0 0 0 Total cooling capacity kW 1.66 2.62 3.07 3.29 3.85 4.13 1.71 3.02 3.81 Sensible cooling capacity kW 1.34 2.16 2.55 2.75 3.25 3.51 1.37 2.38 3.01 3.14 3.78 4.12 Water flow rate l/s 0.08 0.13 0.15 0.16 0.18 0.20 0.08 0.14 0.18 0.19 0.23 0.24 l/h 290 450 530 570 660 710 290 520 655 680 820 880 Water pressure drop kPa 6 14 20 23 30 34 6 18 28.5 31 42 48 Water content l 1.4 kW 2.24 3.79 4.52 4.88 5.79 6.25 2.32 4.31 5.50 Total cooling capacity kW 1.61 2.63 3.23 3.35 3.94 4.23 1.68 2.82 3.53 3.67 4.39 4.76 Sensible cooling capacity kW 1.30 2.15 2.66 2.76 3.27 3.54 1.36 2.28 2.86 2.98 3.59 3.91 Water flow rate l/s 0.08 0.13 0.15 0.16 0.19 0.20 0.08 0.13 0.17 0.18 0.21 0.23 l/h 280 450 555 580 680 730 290 480 605 630 750 820 Water pressure drop kPa 6 15 23 25 33 37 5 15 24 26 36 42 Water content l 1.1 Available static pressure 4V 8V 10V 2V 549 4V 5.5V 6V (M) (H) 141 180 188 231 255 82 295 508 646.5 675 831 918 0 0 0 0 0 (Max) (L) 8V 10V 2V 4V 5.5V 6V (M) (H) 141 180 188 231 255 295 508 646.5 675 831 918 0 0 0 0 0 (Max) (L) 0 0 8V 10V (Max) Cooling mode, two pipes* 3.97 4.75 5.14 NA 1.8 Heating mode, two pipes** Heating capacity 5.74 6.94 7.55 Cooling mode, four pipes* NA 1.4 Heating mode, four pipes*** Heating capacity kW 2.10 3.28 3.96 4.09 4.74 5.05 2.18 3.86 4.82 5.01 5.89 6.31 Water flow rate l/s 0.05 0.08 0.10 0.10 0.12 0.12 0.05 0.09 0.12 0.12 0.14 0.15 180 290 350 360 420 440 190 340 425 440 520 550 6 7.5 8 11 12 3 7 10.5 11 15 16 NA l/h Water pressure drop kPa 3 Water content l 0.5 0.6 Electric heater 230V ±10% - 1ph 230V ±10% - 1ph 230V ±10% - 1ph Maximum capacity W 2000 2000 2000 Current drawn A 9.1 9.1 9.1 Sound levels AIR TREATMENT Sound power level (global) dB(A) 32 43 47 51 55 58 32 43 49 51 55 58 32 43 49 51 55 58 Power input W 4 11 18 24 43 58 4 11 21 24 43 58 4 11 21 24 43 58 Current drawn A 0.04 0.09 0.13 0.17 0.28 0.39 0.04 0.09 0.15 Electrical data, motor 0.17 0.28 0.39 0.04 0.09 0.15 FCEER [energy class] - 2 pipes 235 [A] 243 [A] FCCOP [energy class] 346 [A] 355 [A] FCEER [energy class] - 4 pipes 176 [B] 187 [A] FCCOP [energy class] 288 [A] 322 [A] 0.17 0.28 0.39 Fan speed: L = Low, M = Medium, H = High * Eurovent conditions: Entering air temperature = 27°C db/47% rh – entering water temperature = 7°C, water temperature difference = 5 K. ** Eurovent conditions: Entering air temperature = 20°C, entering water temperature = 50°C, same water flow rate as in cooling. *** Eurovent conditions: Entering air temperature = 20°C, entering water temperature = 70°C, water temperature difference = 10 K. Eurovent certified data 644 C A R R I E R 2 0 1 6 / 2 0 1 7