AHI Carrier Catalog | Page 644
Physical and electrical data at Eurovent conditions
42NL - Size 5
With G1 filter - without plenum
42NL
529
Fan speed
2V
(Eurovent certification speeds)
(L)
Air flow
l/s
82
m3/h
539
5V
6V
(M)
(H)
141
172
188
231
255
82
295
508
618
675
831
918
Pa
0
0
0
0
0
0
Total cooling capacity
kW
1.66 2.62 3.07 3.29 3.85 4.13 1.71 3.02 3.81
Sensible cooling capacity
kW
1.34 2.16 2.55 2.75 3.25 3.51 1.37 2.38 3.01
3.14 3.78 4.12
Water flow rate
l/s
0.08 0.13 0.15 0.16 0.18 0.20 0.08 0.14 0.18
0.19 0.23 0.24
l/h
290
450
530
570
660
710
290
520
655
680
820
880
Water pressure drop
kPa
6
14
20
23
30
34
6
18
28.5
31
42
48
Water content
l
1.4
kW
2.24 3.79 4.52 4.88 5.79 6.25 2.32 4.31 5.50
Total cooling capacity
kW
1.61 2.63 3.23
3.35 3.94 4.23 1.68 2.82 3.53
3.67 4.39 4.76
Sensible cooling capacity
kW
1.30 2.15 2.66
2.76 3.27 3.54 1.36 2.28 2.86
2.98 3.59 3.91
Water flow rate
l/s
0.08 0.13 0.15
0.16 0.19 0.20 0.08 0.13 0.17
0.18 0.21 0.23
l/h
280
450
555
580
680
730
290
480
605
630
750
820
Water pressure drop
kPa
6
15
23
25
33
37
5
15
24
26
36
42
Water content
l
1.1
Available static pressure
4V
8V
10V
2V
549
4V
5.5V
6V
(M)
(H)
141
180
188
231
255
82
295
508
646.5 675
831
918
0
0
0
0
0
(Max) (L)
8V
10V
2V
4V
5.5V
6V
(M)
(H)
141
180
188
231
255
295
508
646.5 675
831
918
0
0
0
0
0
(Max) (L)
0
0
8V
10V
(Max)
Cooling mode, two pipes*
3.97 4.75 5.14
NA
1.8
Heating mode, two pipes**
Heating capacity
5.74 6.94 7.55
Cooling mode, four pipes*
NA
1.4
Heating mode, four pipes***
Heating capacity
kW
2.10 3.28 3.96
4.09 4.74 5.05 2.18 3.86 4.82
5.01 5.89 6.31
Water flow rate
l/s
0.05 0.08 0.10
0.10 0.12 0.12 0.05 0.09 0.12
0.12 0.14 0.15
180
290
350
360
420
440
190
340
425
440
520
550
6
7.5
8
11
12
3
7
10.5
11
15
16
NA
l/h
Water pressure drop
kPa
3
Water content
l
0.5
0.6
Electric heater
230V ±10% - 1ph
230V ±10% - 1ph
230V ±10% - 1ph
Maximum capacity
W
2000
2000
2000
Current drawn
A
9.1
9.1
9.1
Sound levels
AIR TREATMENT
Sound power level (global)
dB(A) 32
43
47
51
55
58
32
43
49
51
55
58
32
43
49
51
55
58
Power input
W
4
11
18
24
43
58
4
11
21
24
43
58
4
11
21
24
43
58
Current drawn
A
0.04 0.09 0.13 0.17 0.28 0.39 0.04 0.09 0.15
Electrical data, motor
0.17 0.28 0.39 0.04 0.09 0.15
FCEER [energy class] - 2 pipes
235
[A]
243
[A]
FCCOP [energy class]
346
[A]
355
[A]
FCEER [energy class] - 4 pipes
176
[B]
187
[A]
FCCOP [energy class]
288
[A]
322
[A]
0.17 0.28 0.39
Fan speed: L = Low, M = Medium, H = High
* Eurovent conditions: Entering air temperature = 27°C db/47% rh – entering water temperature = 7°C, water temperature difference = 5 K.
** Eurovent conditions: Entering air temperature = 20°C, entering water temperature = 50°C, same water flow rate as in cooling.
*** Eurovent conditions: Entering air temperature = 20°C, entering water temperature = 70°C, water temperature difference = 10 K.
Eurovent certified data
644
C
A
R
R
I
E
R
2
0
1
6
/
2
0
1
7