AHI Carrier Catalog | Page 641

HYDRONIC DUCTED FAN COIL UNITS  42NL & 42NH Physical and electrical data at Eurovent conditions 42NL - Size 4 With G1 filter - without plenum 42NL 425 435 Fan speed R6 R5 R4 (Eurovent certification speeds) (L) (M) (H) l/s 129 149 209 234 m3/h 464 537 751 Pa 0 0 Total cooling capacity kW 2.43 Sensible cooling capacity kW 1.99 Water flow rate l/s R1 R6 R5 R4 (Max) (L) (M) (H) 267 301 129 149 842 960 1085 464 0 0 0 0 2.75 3.54 3.83 4.14 2.27 2.98 3.25 3.57 0.12 0.13 0.17 0.18 l/h 420 470 610 Water pressure drop kPa 14 18 27 Water content l 1.0 kW 3.44 Air flow Available static pressure R3 R2 R3 R2 R1 209 234 267 301 537 751 842 960 1085 0 0 0 0 0 0 4.43 2.76 3.20 4.36 4.79 5.29 5.76 3.86 2.18 2.52 3.46 3.83 4.27 4.70 0.20 0.21 0.13 0.15 0.21 0.23 0.25 0.28 660 710 760 470 550 750 820 910 990 31 36 40 16 21 36 43 51 59 3. 96 4.58 6.34 7.06 7.93 8.80 (Max) Cooling mode, two pipes* 1.3 Heating mode, two pipes** Heating capacity 3.95 5.30 5.81 6.38 6.91 Cooling mode, four pipes* Total cooling capacity kW 2.52 2.84 3.69 4.00 4.37 4.72 Sensible cooling capacity kW 2.05 2.33 3.08 3.37 3.72 4.07 Water flow rate l/s 0.12 0.14 0.18 0.19 0.21 0.23 l/h 430 490 630 690 750 810 Water pressure drop kPa 19 24 38 43 50 58 Water content l 0.9 Heating capacity kW 3.62 4.20 5.71 6.27 6.90 7.46 Water flow rate l/s 0.09 0.10 0.14 0.15 0.17 0.18 320 370 500 550 610 660 29 50 59 70 80 NA Heating mode, four pipes*** NA l/h Water pressure drop kPa 22 Water content l 0.5 Electric heater 230V ±10% - 1ph 230V ±10% - 1ph Maximum capacity W 2000 2000 Current drawn A 9.1 9.1 Sound power level (global) dB(A) 45 48 55 58 60 63 45 48 55 58 60 63 Power input W 57 69 98 113 129 157 57 69 98 113 129 157 Current drawn A 0.25 0.30 0.43 0.49 0.57 0.69 0.25 0.30 0.43 0.49 0.57 0.69 FCEER [energy class] - 2 pipes 41 [E] 47 [E] FCCOP [energy class] 59 [E] Electrical data, motor 68 [E] FCEER [energy class] - 4 pipes 35 [E] FCCOP [energy class] 62 [E] Fan speed: L = Low, M = Medium, H = High * Eurovent conditions: Entering air temperature = 27°C db/47% rh – entering water temperature = 7°C, water temperature difference = 5 K. ** Eurovent conditions: Entering air temperature = 20°C, entering water temperature = 50°C, same water flow rate as in cooling. *** Eurovent conditions: Entering air temperature = 20°C, entering water temperature = 70°C, water temperature difference = 10 K. AIR TREATMENT Sound levels CONTROLS Eurovent certified data C A R R I E R 2 0 1 6 / 2 0 1 7 641