AHI Carrier Catalog | Page 597

CASSETTE FAN COIL UNITS  42GW Physical data 42GW 200 300 400 Coil type 2 pipes 2 pipes 2 pipes Fan speed* 1 2 3 1 2 3 1 2 3 l/s 183 125 100 204 140 89 249 173 134 Total cooling capacity kW 2,39 1,78 1,55 4,02 2,89 1,88 4,74 3,52 2,8 Sensible cooling capacity kW 2,01 1,5 1,3 3,07 2,19 1,42 3,67 2,7 2,1 Water flow rate l/s 0,11 0,09 0,08 0,19 0,14 0,09 0,23 0,17 0,13 l/h 410 310 270 690 500 320 810 600 480 kPa 10 5 4 14 7 3 18 10 6 Heating capacity kW 3,2 2,5 2,2 4,53 3,72 2,32 6,2 4,61 3,7 Water pressure drop kPa 8 5 4 13 7 3 14 8 5 Water content l 0.55 Sound power level dB(A) 49 40 36 53 44 35 57 48 42 Sound pressure level** dB(A) 40 31 27 44 35 26 48 39 33 Power input W 58 35 25 58 34 17 99 58 38 Current input A 0.27 0.17 0.12 0.24 0.14 0.07 0.41 0.24 0.16 Air flow Cooling mode Water pressure drop Heating mode Eurovent energy class FCEER/FCCOP 1.1 1.1 D/D C/C D/D Electric heater (high capacity) W 1500 2500 2500 Current input (high capacity) A 6.3 10.4 10.4 42GW 500 600 701 Coil type 2 pipes 2 pipes 2 pipes Fan speed* Air flow l/s 1 2 3 1 2 3 1 2 3 272 199 147 321 229 139 402 299 166 Total cooling capacity kW 6,1 4,45 3,36 7,22 5,49 3,71 8,67 6,53 4,06 Sensible cooling capacity kW 4,5 3,37 2,53 5,46 4,09 2,69 6,4 4,9 2,99 Water flow rate l/s 0,29 0,21 0,16 0,34 0,26 0,18 0,41 0,31 0,19 l/h 1050 760 580 1240 940 640 1490 1120 700 kPa 22 12 7 11 6 3 20 12 5 Water pressure drop AIR TREATMENT Cooling mode Heating mode Heating capacity kW 8,07 5,97 4,48 9,99 7,4 4,61 11,7 9,3 5,21 Water pressure drop kPa 17 10 6 10 6 3 18 11 5 Water content l 1.6 Sound power level dB(A) 49 40 35 54 46 38 59 52 40 Sound pressure level** dB(A) 40 31 26 45 37 29 50 43 31 2.4 Power input W 66 41 28 88 61 34 125 92 44 Current input A 0.30 0.17 0.12 0.46 0.27 0.14 0.63 0.41 0.19 Eurovent energy class FCEER/FCCOP C/C C/C C/C Electric heater (high capacity) W 3000 3000 3000 Current input (high capacity) A 12.5 12.5 12.5 CONTROLS 2.4 Based on Eurovent conditions: Cooling mode (2 and 4-pipe coil): entering air temperature 27°C db/1 9°C wb, entering/leaving water temperature 7/12°C, high fan speed. Heating mode (2-pipe coil): entering air temperature 20°C, entering water temperature 50°C, high fan speed, water flow rate as cooling mode. Heating mode (4-pipe coil): entering air temperature 20°C, entering water temperature 70°C, high fan speed, water ∆t = 10 K * Fan speeds: 1 = high, 2 = medium, 3 = low ** Sound pressure level and NR values are based on a hypothetical sound attenuation for the room of -9 dB(A). Note: Electrical heater version is available on all 2-pipe units. C A R R I E R 2 0 1 6 / 2 0 1 7 597