AIR-COOLED LIQUID CHILLERS 30RBV 017-021
Physical data
30RBV
17
21
18,6
Standard unit
C1
Nominal capacity
kW
15,6
Full load performances*
C1
EER
kW/kW
3,3
3,1
C1
Eurovent class cooling
A
A
C2
Nominal capacity
kW
21,6
25,5
C2
EER
kW/kW
4,0
3,9
C2
Eurovent class cooling
A
A
ESEER
4,48
4,56
Seasonal efficiency
COOLING
Cooling
Sound levels
Standard unit
Sound power level (2)
dB(A)
71
74
Sound pressure level at 10 m (3)
dB(A)
40
43
Length (5)
mm
1109
1109
Width
mm
584
584
Height
mm
1579
1579
Standard unit
kg
168,9
176,9
Compressors
Rotary compressor
1
1
Refrigerant
R410A
Charge (1)
kg
6,25
6,25
Minimum capacity (6)
%
33%
41%
Condenser
Grooved copper tubes, aluminium fins
Fans - Standard unit
Axial type fan
Dimensions - Standard unit
Operating Weight (1)
2
2
Maximum total air flow
l/s
2000
2400
Maximum rotational speed
rps
14
16
Evaporator
Brazed plate heat exchanger
Water volume
l
1,52
1,9
Max water-side operating pressure without hydronic module
kPa
1000
1000
Hydronic module (option)
Pump, relief valve, paddle flow switch, expansion tank (option)
Pump
Centrifugal pump (fixed speed or variable speed)
Expansion tank volume
l
8
8
Max. water-side operating pressure with hydronic module (4)
kPa
300
300
Inlet diameter (BSP GAS)
inch
1
1
Outlet diameter (BSP GAS)
inch
1
1
Inlet diameter (BSP GAS)
inch
1-1/4
1-1/4
Outlet diameter (BSP GAS)
inch
1
1
Diameter (BSP GAS)
inch
1/2
1/2
Chassis paint colour
Colour code:
RAL 7035
RAL 7035
AIR TREATMENT
Quantity
HEATING HEATING
Capacity control
Water connections (Without Hydronic Module)
Water connections (With Hydronic Module)
Water Filling System (Option 287)
In accordance with standard EN 14511-3:2013
Cooling mode conditions : evaporator water entering/leaving temperature 12°C/7°C, outside air temperature 35°C, evaporator fooling factor 0m² K/W
Cooling mode conditions : evaporator water entering/leaving temperature 23°C/18°C, outside air temperature 35°C, evaporator fooling factor 0m² K/W
Values are guidelines only. Refer to the unit nameplate.
In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with
ISO 9614-1 and certified by Eurovent.
(3) In dB ref 20 μPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from
the sound power level Lw(A).
(4) Min. water-side operating pressure with fixed speed hydronic module is 50 kPa and with variable speed hydronic module is 40 kPa.
(5) Length = 1141 mm if main disconnect switch
(6) Cooling Eurovent condition
C
A
R
R
I
E
R
2
0
1
6
/
2
0
1
7
59
CONTROLS
*
C1
C2
(1)
(2)