AHI Carrier Catalog | Page 59

AIR-COOLED LIQUID CHILLERS 30RBV 017-021 Physical data 30RBV 17 21 18,6 Standard unit C1 Nominal capacity kW 15,6 Full load performances* C1 EER kW/kW 3,3 3,1 C1 Eurovent class cooling A A C2 Nominal capacity kW 21,6 25,5 C2 EER kW/kW 4,0 3,9 C2 Eurovent class cooling A A ESEER 4,48 4,56 Seasonal efficiency COOLING Cooling Sound levels Standard unit Sound power level (2) dB(A) 71 74 Sound pressure level at 10 m (3) dB(A) 40 43 Length (5) mm 1109 1109 Width mm 584 584 Height mm 1579 1579 Standard unit kg 168,9 176,9 Compressors Rotary compressor 1 1 Refrigerant R410A Charge (1) kg 6,25 6,25 Minimum capacity (6) % 33% 41% Condenser Grooved copper tubes, aluminium fins Fans - Standard unit Axial type fan Dimensions - Standard unit Operating Weight (1) 2 2 Maximum total air flow l/s 2000 2400 Maximum rotational speed rps 14 16 Evaporator Brazed plate heat exchanger Water volume l 1,52 1,9 Max water-side operating pressure without hydronic module kPa 1000 1000 Hydronic module (option) Pump, relief valve, paddle flow switch, expansion tank (option) Pump Centrifugal pump (fixed speed or variable speed) Expansion tank volume l 8 8 Max. water-side operating pressure with hydronic module (4) kPa 300 300 Inlet diameter (BSP GAS) inch 1 1 Outlet diameter (BSP GAS) inch 1 1 Inlet diameter (BSP GAS) inch 1-1/4 1-1/4 Outlet diameter (BSP GAS) inch 1 1 Diameter (BSP GAS) inch 1/2 1/2 Chassis paint colour Colour code: RAL 7035 RAL 7035 AIR TREATMENT Quantity HEATING HEATING Capacity control Water connections (Without Hydronic Module) Water connections (With Hydronic Module) Water Filling System (Option 287) In accordance with standard EN 14511-3:2013 Cooling mode conditions : evaporator water entering/leaving temperature 12°C/7°C, outside air temperature 35°C, evaporator fooling factor 0m² K/W Cooling mode conditions : evaporator water entering/leaving temperature 23°C/18°C, outside air temperature 35°C, evaporator fooling factor 0m² K/W Values are guidelines only. Refer to the unit nameplate. In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with ISO 9614-1 and certified by Eurovent. (3) In dB ref 20 μPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from the sound power level Lw(A). (4) Min. water-side operating pressure with fixed speed hydronic module is 50 kPa and with variable speed hydronic module is 40 kPa. (5) Length = 1141 mm if main disconnect switch (6) Cooling Eurovent condition C A R R I E R 2 0 1 6 / 2 0 1 7 59 CONTROLS * C1 C2 (1) (2)