AHI Carrier Catalog | Page 571

MEDIUM TEMPERATURE WATER-TO-WATER HEAT PUMPS   30XWHP-ZE/30XWHV-ZE Physical data 30XWHP ZE0301 30XWHP ZE0401 30XWHP ZE0451 30XWHP ZE0551 30XWHP ZE0601 kW 321 449 510 648 695 30XWHP ZE Heating Performance Information Heating Capacity* kW/kW 6,25 6,72 6,64 6,83 6,63 Maximum hot water temperature °C 70 70 70 70 Number of Refrigerant Circuit -- 1 1 1 1 70 1 kg 2072/1953 2981/2763 3020/2802 3912/3593 3947/3628 2724/927 /1617 3059/936/ 1743 3059/936/ 1743 3290/1065/ 1950 3290/1070/ 1950 Heating Efficiency COP Operating/Shipping Weight Unit Dimensions LxWxH mm Electrical Information Unit Voltage: V-Ph-Hz 400(+/-10%) -3-50 400(+/-10%) -3-50 400(+/-10%) -3-50 400(+/-10%) -3-50 400(+/-10%) -3-50 Standby Power: kW 0,05 0,05 0,05 0,05 0,05 Power Factor: -- 0,88 0,90 0,90 0,90 0,90 Maximum Current A 130 176 196 239 263 Start Up Current A 303 414 414 587 587 Current at Eurovent Conditions A 87 109 123 146 162 Maximum Current A -- -- -- -- -- Start Up Current A -- -- -- -- -- Current at Eurovent Conditions A -- -- -- -- -- 30XWHP ZE0651 30XWHP ZE0801 30XWHP ZE0901 30XWHP ZE1001 30XWHP ZE1101 kW kW/kW 761 6,66 916 6,73 1019 6,79 1165 6,81 1285 6,59 °C -kg mm 70 1 3965/3646 3290/1070/ 1950 70 2 6872/6218 4795/1039/ 1997 70 2 6950/6296 4795/1039/ 1997 70 2 7542/6682 4730/1162/ 2051 70 2 7752/6892 4730/1162/ 2051 V-Ph-Hz 400(+/-10%) -3-50 kW 0,05 -0,82 400(+/-10%) -3-50 0,05 0,89 400(+/-10%) -3-50 0,05 0,90 400(+/-10%) -3-50 0,05 0,90 400(+/-10%) -3-50 0,05 0,90 A A A 284 587 176 176 414 109 196 414 123 239 587 146 239 587 146 A A A ---- 176 414 109 196 414 123 196 414 123 239 587 146 Amps (Un) Circuit 1 30XWHP ZE HEATING Circuit 2 Heating COP Maximum hot water temperature Number of Refrigerant Circuit Operating/Shipping Weight Unit Dimensions LxWxH Electrical Information Unit Voltage: Standby Pow er: Power Factor: Amps (Un) Circuit 1 Maximum Current Start Up Current Current at Eurovent Conditions Circuit 2 Maximum Current Start Up Current Current at Eurovent Conditions * Heating mode conditions: Condenser water heat exchanger, entering/leaving water temperature 30°C/35°C, fouling factor 0 m² K/W. Evaporator water heat exchanger, entering/leaving water temperature 10°C/7°C, fouling factor 0 m² K/W. All performances are compliant with EN14511-3 : 2013. Sound power level according to ISO9614-1. Unit is outside of the scope of AHRI Water-Cooled Water Chilling Packages Using Vapor Compression Cycle Certification Program, but is rated in accordance with AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI). Preliminary product data for information only. Final product data will be submitted by Carrier to Eurovent company during 2016. C A R R I E R 2 0 1 6 / 2 0 1 7 571 CONTROLS Heating Capacity* Heating Efficiency AIR TREATMENT Performance Information