AHI Carrier Catalog | Page 550

Options Options No. Condensing temperature limitation 150B Limitation of the maximum condenser leaving water temperature to 45°C Control for low condensing temperature systems Energy Management Module EMM Touch Pilot control, 7” user interface Leak detection HEATING Compliance with Swiss regulations Compliance with Australian regulations Low noise level Welded evaporator water connection kit Welded condenser water connection kit Flanged evaporator water connection kit Flanged condenser water connection kit Thermal compressor insulation 230V electrical plug Carrier Connect link (BSS regions only) Description Advantages Use 30XWH Reduced maximum power input and current absorption: power cables and protection elements can therefore be downsized 152 Output signal (0-10 V) to control the condenser Simple installation: for applications with cold water inlet valve water at condenser inlet (ex. ground-source, groundwater-source, superficial water-source applications) the signal permits to control a 2 or 3-way valve to maintain condenser water temperature (and so condensing pressure) at acceptable values 156 Control board with additional inputs/outputs. See Extended remote control capabilities (Set-point Energy Management Module option chapter reset, ice storage end, demand limits, boiler on/ off command...) 158A Touch Pilot control supplied with a 7 inch colour Enhanced ease of use touch screen user interface 159 0-10 V signal to report any refrigerant leakage in Immediate customer notification of refrigerant the unit directly on the controlller (the leak detec- losses to the atmosphere, allowing timely corrector itself must be supplied by the customer) tive actions 197 Additional tests on the water heat exchangers: Conformance with Swiss regulations supply (additional of PED documents) supplementary certificates and test certifications 200 Unit approved to Australian code Conformance with Australian regulations 254-1762 257 266 Evaporator and suction piping sound insulation Victaulic piping connections with welded joints 3 dB(A) quiter than standard unit Easy installation 254-1762 254-1762 267 Victaulic piping connections with welded joints Easy installation 254-1762 268 Victaulic piping connections with flanged joints Easy installation 254-1762 269 Victaulic piping connections with flanged joints Easy installation 254-1762 271 The compressor is covered with a thermal insulation layer 230V AC power supply source provided with plug socket and transformer (180 VA, 0,8 Amps) 3G router board NOTE 1: require option 149 NOTE 2: when more than one machine is installed on site, only one of them shall be equipped with option 298 while all of them must be equipped with option 149 NOTE 3: if a CARRIER-PSM is on site, option 298 shall be integrated in the PSM while option 149 is still mandatory for each single unit. Prevents air humidity to condensate on the compressor surface Permits connection of a laptop or an electrical device during unit commissioning or servicing Enabler for Carrier Connect service offer 254-1762 284 298 254-1762 254-1762 254-1762 254-1762 254-1762 254-1762 254-1762 254-1762 Accessories Accessories Description Advantages Use 30XWH Very low noise level (-20 dB(A) compared to standard unit) Sound absorbing cabinet for single-circuit units Significantly quieter (-20 dB(A)) than a unit without this option 254-862 Very low noise level (-20 dB(A) compared to standard unit) Sound absorbing cabinet for twin-circuit units Significantly quieter (-20 dB(A)) than a unit without this option 1002-1252, 1352, 1452, 1552, 1314, 1464 550 C A R R I E R 2 0 1 6 / 2 0 1 7