Options
Options
No.
Condensing temperature
limitation
150B Limitation of the maximum condenser leaving
water temperature to 45°C
Control for low condensing
temperature systems
Energy Management
Module EMM
Touch Pilot control, 7” user
interface
Leak detection
HEATING
Compliance with Swiss
regulations
Compliance with Australian
regulations
Low noise level
Welded evaporator water
connection kit
Welded condenser water
connection kit
Flanged evaporator water
connection kit
Flanged condenser water
connection kit
Thermal compressor
insulation
230V electrical plug
Carrier Connect link (BSS
regions only)
Description
Advantages
Use 30XWH
Reduced maximum power input and current
absorption: power cables and protection elements can therefore be downsized
152
Output signal (0-10 V) to control the condenser
Simple installation: for applications with cold
water inlet valve
water at condenser inlet (ex. ground-source,
groundwater-source, superficial water-source
applications) the signal permits to control a 2
or 3-way valve to maintain condenser water
temperature (and so condensing pressure) at
acceptable values
156
Control board with additional inputs/outputs. See Extended remote control capabilities (Set-point
Energy Management Module option chapter
reset, ice storage end, demand limits, boiler on/
off command...)
158A Touch Pilot control supplied with a 7 inch colour Enhanced ease of use
touch screen user interface
159
0-10 V signal to report any refrigerant leakage in Immediate customer notification of refrigerant
the unit directly on the controlller (the leak detec- losses to the atmosphere, allowing timely corrector itself must be supplied by the customer)
tive actions
197
Additional tests on the water heat exchangers:
Conformance with Swiss regulations
supply (additional of PED documents) supplementary certificates and test certifications
200
Unit approved to Australian code
Conformance with Australian regulations
254-1762
257
266
Evaporator and suction piping sound insulation
Victaulic piping connections with welded joints
3 dB(A) quiter than standard unit
Easy installation
254-1762
254-1762
267
Victaulic piping connections with welded joints
Easy installation
254-1762
268
Victaulic piping connections with flanged joints
Easy installation
254-1762
269
Victaulic piping connections with flanged joints
Easy installation
254-1762
271
The compressor is covered with a thermal
insulation layer
230V AC power supply source provided with
plug socket and transformer (180 VA, 0,8 Amps)
3G router board
NOTE 1: require option 149
NOTE 2: when more than one machine is installed on site, only one of them shall be equipped
with option 298 while all of them must be equipped with option 149
NOTE 3: if a CARRIER-PSM is on site, option
298 shall be integrated in the PSM while option
149 is still mandatory for each single unit.
Prevents air humidity to condensate on the
compressor surface
Permits connection of a laptop or an electrical
device during unit commissioning or servicing
Enabler for Carrier Connect service
offer
254-1762
284
298
254-1762
254-1762
254-1762
254-1762
254-1762
254-1762
254-1762
254-1762
Accessories
Accessories
Description
Advantages
Use 30XWH
Very low noise level (-20 dB(A)
compared to standard unit)
Sound absorbing cabinet for
single-circuit units
Significantly quieter (-20 dB(A)) than a
unit without this option
254-862
Very low noise level (-20 dB(A)
compared to standard unit)
Sound absorbing cabinet for
twin-circuit units
Significantly quieter (-20 dB(A)) than a
unit without this option
1002-1252,
1352, 1452,
1552, 1314,
1464
550