AHI Carrier Catalog | Page 549

WATER-COOLED SCREW CHILLERS  30XWH 254-1762 Options Options No. Description Advantages Use 30XWH Medium-temperature brine solution 5 Covers specific applications such as ice storage and industrial processes Only sizes 512/562/1012/1154 Low-temperature brine solution 6 Covers specific applications such as ice storage and industrial processes Only sizes 512/562/1012/1154 Light-brine solution, down to -3°C 8 Implementation of new algorithms of control and evaporator redesign to allow chilled brine solution production down to -6°C when ethylene glycol is used (-3°C with propylene glycol) Implementation of new algorithms of control and evaporator redesign to allow chilled brine solution production down to -12°C when ethylene glycol is used (-8°C with propylene glycol) Implementation of new algorithms of control to allow chilled brine solution production down to -3°C when ethylene glycol is used (0°C with propylene glycol) The unit is equipped with flanges that allow disassembly of the unit on site Unit equipped with supplementary water outlet temperature sensor kit to be field-installed allowing master/slave operation of two units connected in parallel Unit power connection via one main supply connection Unit without disconnect switch, but with shortcircuit protection device Matches with most application requirements for ground-sourced heat pumps and fits with many industrial processes requirements 254-1762 Facilitates installation in plant rooms with limited access Optimised operation of two chillers connected in parallel with operating time equalisation Only sizes 1612/1652/1702/1762 254-1762 Quick and easy installation 1002-1762 Permits an external electrical disconnect system for the unit (field-supplied), while ensuring unit short circuit protection Quick and easy installation: the control of fixed speed pumps is embedded in the unit control Quick and easy installation: the control of fixed speed pumps is embedded in the unit control Quick and easy installation: the control of fixed speed pumps is embedded in the unit control Minimizes thermal dispersions condenser side (key option for heat pump or heat recovery applications) and allows compliancy with special installation criteria (hot parts insulated) Allow isolation of various refrigerant circuit components for simplified service and maintenance Easy to install, depending on site. Reduced pressure drops Easy to install, depending on site. Reduced pressure drops Covers applications with a high water column evaporator side (typically high buildings) 254-1762 82A Evaporator pump electrical power / control circuit 84 Unit equipped with an electrical power and control circuit for one pump evaporator side Evaporator dual pumps electrical power / control circuit Condenser pump electrical power / control circuit 84D Unit equipped with an electrical power and control circuit for two pumps evaporator side 84R Unit equipped with an electrical power and control circuit for one pump condenser side Condenser insulation 86 Thermal condenser insulation Service valve set 92 Liquid line valve (evaporator inlet) and compressor suction line valve 100C Evaporator with one pass on the water side. Evaporator inlet and outlet on opposite sides. 102C Condenser with one pass on the water side. Condenser inlet and outlet on opposite sides. 104 Reinforced evaporator for extension of the maximum water-side service pressure to 21 bar (standard 10 bar) 104A Reinforced condenser for extension of the maximum water-side service pressure to 21 bar (standard 10 bar) 107 Evaporator with reversed water inlet/outlet Evaporator with one pass Condenser with one pass 21 bar evaporator 21 bar condenser Reversed evaporator water connections Reversed condenser water connections JBus gateway Easy installation on sites with specific requirements 107A Condenser with reversed water inlet/outlet Easy installation on sites with specific requirements 148B Two-directional communication board complying Connects the unit by communication with JBus protocol bus to a building management system 148D Two-directional communication board complying Connects the unit by communication with Lon Talk protocol bus to a building management system 149 Two-directional high-speed communication using Easy and high-speed connection by ethernet line BACnet protocol over Ethernet network (IP) to a building management system. Allows access to multiple unit parameters 150 Optimized compressor for operation at high Increased condenser leaving water tempecondensing temperature rature up to 63°C. Allows applications with high condensing temperature (heat pumps, installations with not generously sized dry-coolers or more generally, installations with dry-coolers in hot climate). NOTE: to ensure control of the condenser leaving water temperature, this option must be fitted with 30XWH units. LON gateway Bacnet over IP gateway High condensing temperature C A R R I E R Covers applications with a high water column condenser side (typically high buildings) 2 0 1 6 / 2 0 1 7 252-1252, 1314 252-1252, 1314 HEATING 81 252-1252, 1314 254-1762 254-1762 254-1762 254-1762 AIR TREATMENT Single power connection point No disconnect switch, but short circuit protection 254-1762 254-1762 254-1762 254-1762 254-1762 254-1762 254-1762 254-1762 CONTROLS Unit supplied in two assem- 51 bled parts Master/slave operation 58 549