Electrical data, standard units
High-efficiency units
30XWHP
HEATING
Power circuit
Nominal power supply
V-ph-Hz
Voltage range
V
Control circuit
Nominal start-up current*
Circuit A
A
Circuit B
A
Option 81
A
Maximum start-up current**
Circuit A
A
Circuit B
A
Option 81
A
Cosine phi
Nominal***
Maximum****
Total harmonic distortion****
%
Maximum power input†
Circuit A
kW
Circuit B
kW
Option 81
kW
Nominal current drawn***
Circuit A
A
Circuit B
A
Option 81
A
Maximum current drawn (Un)†
Circuit A
A
Circuit B
A
Option 81
A
Maximum current drawn (Un -10%)****
Circuit A
A
Circuit B
A
Option 81
A
Maximum power input with option 150B†
Circuit A
kW
Circuit B
kW
Option 81
kW
Maximum current drawn (Un) with option 150B†
Circuit A
A
Circuit B
A
Option 81
A
*
**
***
****
†
512
562
712
812
862
1012 1162 1314 1464 1612 1762
400-3-50
360-440
24 V via the built-in transformer
414
-
414
-
587
-
587
-
587
-
414
414
556
414
414
574
587
414
747
587
587
780
587
587
801
587
587
819
414
-
414
-
587
-
587
-
587
-
414
414
631
414
414
656
587
414
829
587
587
882
587
587
904
587
587
938
0.88
0.90
0
0.89
0.90
0
0.88
0.90
0
0.89
0.91
0
0.90
0.92
0
0.86
0.89
0
0.87
0.90
0
0.88
0.90
0
0.88
0.90
0
0.89
0.91
0
0.90
0.92
0
135
-
151
-
184
-
200
-
223
-
134
134
267
151
151
301
184
151
334
184
184
367
200
200
399
223
223
447
144
-
162
-
193
-
214
-
232
-
144
144
288
162
162
324
193
162
355
193
193
386
214
214
427
232
232
464
217
-
242
-
295
-
317
-
351
-
217
217
434
242
242
484
295
242
537
295
295
590
317
317
634
351
351
702
230
-
260
-
304
-
340
-
358
-
230
230
460
260
260
520
304
260
564
304
304
608
340
340
680
358
358
716
118
-
133
-
173
-
183
-
207
-
118
118
235
133
133
265
173
133
305
173
173
346
183
183
365
207
207
414
191
-
212
-
278
-
290
-
325
-
191
191
382
212
212
424
278
212
490
278
278
556
290
290
580
325
325
650
Instantaneous start-up current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced start-up current of the largest compressor). Values obtained
at standard Eurovent unit operating conditions: evaporator entering/leaving water temperature = 12°C/7°C, condenser entering/leaving water temperature = 30°C/35°C.
Instantaneous start-up current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced start-up current of the largest compressor). Values obtained
at operation with maximum unit power input.
Values obtained at standard Eurovent unit operating conditions: evaporator entering/leaving water temperature = 12°C/7°C, condenser entering/leaving water temperature = 30°C/35°C
Values obtained at operation with maximum unit power input.
Values obtained at operation with maximum unit power input. Values given on the unit name plate.