AHI Carrier Catalog | Page 542

Electrical data, standard units High-efficiency units 30XWHP HEATING Power circuit Nominal power supply V-ph-Hz Voltage range V Control circuit Nominal start-up current* Circuit A A Circuit B A Option 81 A Maximum start-up current** Circuit A A Circuit B A Option 81 A Cosine phi Nominal*** Maximum**** Total harmonic distortion**** % Maximum power input† Circuit A kW Circuit B kW Option 81 kW Nominal current drawn*** Circuit A A Circuit B A Option 81 A Maximum current drawn (Un)† Circuit A A Circuit B A Option 81 A Maximum current drawn (Un -10%)**** Circuit A A Circuit B A Option 81 A Maximum power input with option 150B† Circuit A kW Circuit B kW Option 81 kW Maximum current drawn (Un) with option 150B† Circuit A A Circuit B A Option 81 A * ** *** **** † 512 562 712 812 862 1012 1162 1314 1464 1612 1762 400-3-50 360-440 24 V via the built-in transformer 414 - 414 - 587 - 587 - 587 - 414 414 556 414 414 574 587 414 747 587 587 780 587 587 801 587 587 819 414 - 414 - 587 - 587 - 587 - 414 414 631 414 414 656 587 414 829 587 587 882 587 587 904 587 587 938 0.88 0.90 0 0.89 0.90 0 0.88 0.90 0 0.89 0.91 0 0.90 0.92 0 0.86 0.89 0 0.87 0.90 0 0.88 0.90 0 0.88 0.90 0 0.89 0.91 0 0.90 0.92 0 135 - 151 - 184 - 200 - 223 - 134 134 267 151 151 301 184 151 334 184 184 367 200 200 399 223 223 447 144 - 162 - 193 - 214 - 232 - 144 144 288 162 162 324 193 162 355 193 193 386 214 214 427 232 232 464 217 - 242 - 295 - 317 - 351 - 217 217 434 242 242 484 295 242 537 295 295 590 317 317 634 351 351 702 230 - 260 - 304 - 340 - 358 - 230 230 460 260 260 520 304 260 564 304 304 608 340 340 680 358 358 716 118 - 133 - 173 - 183 - 207 - 118 118 235 133 133 265 173 133 305 173 173 346 183 183 365 207 207 414 191 - 212 - 278 - 290 - 325 - 191 191 382 212 212 424 278 212 490 278 278 556 290 290 580 325 325 650 Instantaneous start-up current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced start-up current of the largest compressor). Values obtained at standard Eurovent unit operating conditions: evaporator entering/leaving water temperature = 12°C/7°C, condenser entering/leaving water temperature = 30°C/35°C. Instantaneous start-up current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced start-up current of the largest compressor). Values obtained at operation with maximum unit power input. Values obtained at standard Eurovent unit operating conditions: evaporator entering/leaving water temperature = 12°C/7°C, condenser entering/leaving water temperature = 30°C/35°C Values obtained at operation with maximum unit power input. Values obtained at operation with maximum unit power input. Values given on the unit name plate. 542 C A R R I E R 2 0 1 6 / 2 0 1 7