AHI Carrier Catalog | Page 538

Physical data HEATING 30XWH- 852 1002 1052 1154 1252 1352 Heating application as per EN14511-3:2013† - standard unit Condition 2 Nominal heating capacity kW 967 1138 1190 1320 1384 1481 COP kW/kW 4.64 4.48 4.42 4.54 4.73 4.57 Eurovent class heating A A B A A A Heating application †† - standard unit Condition 2 Nominal heating capacity kW 964 1134 1186 1314 1380 1476 COP kW/kW 4.93 4.76 4.74 4.89 5.02 4.88 Sound levels - standard unit Sound power level* dB(A) 99 102 102 102 102 102 Sound pressure level at 1 m** dB(A) 82 84 84 84 83 83 Sound levels - standard unit + option 257*** Sound power level* dB(A) 96 99 99 99 99 99 Sound pressure level at 1 m** dB(A) 78 80 80 80 80 80 Dimensions - standard unit Length mm 2780 4025 4025 4025 4730 4730 Width mm 1442 1036 1036 1156 1156 1156 Height mm 1898 1870 1925 2051 2051 2051 Operating weight**** kg 3492 5370 5408 5698 7066 7267 Compressors Semi-hermetic 06T screw compressors, 50 r/s Circuit A 1 1 1 1 1 1 Circuit B 1 1 1 1 1 Refrigerant**** - standard unit R-134a Circuit A kg 140 85 85 105 120 115 Circuit B kg 85 85 105 120 115 Global Warming Potential (GWP) tonnes 200 122 122 150 172 164 Tonnes of equivalent CO2 of greatest circuit Capacity control Touch Pilot, electronic expansion valves (EXV) Minimum capcity % 15 10 10 10 10 10 Evaporator Multi-pipe flooded type Water volume l 98 182 182 205 301 301 Water connections (Victaulic) in 6 6 6 8 8 8 Drain and vent connections (NPT) in 3/8 3/8 3/8 3/8 3/8 3/8 Max. water-side operating pressure kPa 1000 1000 1000 1000 1000 1000 Condenser Multi-pipe flooded type Water volume l 137 193 193 193 340 340 Water connections (Victaulic) in 8 8 8 8 8 8 Drain and vent connections (NPT) in 3/8 3/8 3/8 3/8 3/8 3/8 Max. water-side operating pressure kPa 1000 1000 1000 1000 1000 1000 1452 1552 1652 1702 1612 4.46 - 1717 4.41 - 1891 4.67 - 1969 4.68 - 1606 4.81 1710 4.80 1884 5.10 1962 5.15 102 83 102 83 102 83 102 83 99 80 99 80 99 80 99 80 4730 1156 2051 7305 4730 1156 2051 7337 4790 1902 1515 8681 4790 1902 1515 8699 1 1 1 1 1 1 1 1 110 110 105 105 195 195 195 195 157 150 279 279 10 10 10 10 301 8 3/8 1000 301 8 3/8 1000 354 8 3/8 1000 354 8 3/8 1000 340 8 3/8 1000 340 8 3/8 1000 426 8 3/8 1000 426 8 3/8 1000 † Eurovent-certified performances in accordance with standard EN14511-3:2013. † † Gross performances, not in accordance with EN14511-3:2013. These performances do not take into account the correction for the proportional heating capacity and power input generated by the water pump to overcome the internal pressure drop in the heat exchanger. Condition 1 : Cooling mode conditions, evaporator water entering/leaving temperature 12°C/7°C, condenser water entering/leaving temperature 30°C/35°C, evaporator fouling factor 0 m².K/W. Condition 2: Cooling mode conditions, condenser water entering/leaving temperature 40°C/45°C, evaporator water entering/leaving temperature 10°C/7°C, evaporator fouling factor 0 m².K/W. * In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with ISO 9614-1 and certified by Eurovent. ** In dB ref 20µPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from the sound power level Lw(A). *** Option 257 = Low noise level. **** Weight shown is guideline only. Please refer to the unit nameplate. Eurovent certified data 538 C A R R I E R 2 0 1 6 / 2 0 1 7