AIR-COOLED LIQUID CHILLERS 30RB 017-040 Physical data 30RB 017 021 026 033 040 Full load performances* C1 Nominal capacity kW 16.4 21.4 27.3 33.3 41.4 C1 EER kW/kW 3.04 3.11 3.08 3.28 2.96 C1 Eurovent Energy Class B A B A B C2 Nominal capacity kW 22.7 29.5 38.6 45.8 56.9 C2 EER kW/kW 3.80 3.86 4.01 4.11 3.52 Seasonal Efficiency* ESEER kW/kW 3.46 3.47 3.44 3.62 3.29 dB(A) 72 74 78 78 80 Standard unit (with hydronic module) kg 189 208 255 280 291 Standard unit (without hydronic module) kg 173 193 237 262 273 Sound Power Level Standard Unit COOLING Cooling Operating weight† Refrigerant R-410A Compressor One hermetic scroll compressor Control Pro-Dialog+ Two twin-speed axial fans, 3 blades One twin-speed axial fan, 7 blades 3530 Air flow 2212 Evaporator Plate heat exchanger 2212 3530 3530 Condenser Copper tubes and aluminium fins Unit with hydronic module Pump One single-speed pump, screen filter, expansion tank, flow switch, pressure gauge, automatic air purge valve, safety valve in 1-1/41 1-1/41 1-1/4 1-1/4 1-1/4 Leaving water connection in 1 1 1-1/4 1-1/4 1-1/4 Nominal operating current A 1.30 1,4 2,4 2,6 2,8 Length mm 1136 1136 1002 1002 1002 Depth mm 584 584 824 824 824 Height mm 1579 1579 1790 1790 1790 Entering water connection HEATING HEATING % Dimensions C1 Cooling mode conditions: Evaporator Water heat exchanger, entering/leaving temperature 12°C/7°C, fouling factor 0 m K/W. Condenser Water heat exchanger, entering/leaving temperature 30°C/35°C, fouling factor 0 m2 K/W. C2 Cooling mode conditions: Evaporator Water heat exchanger, entering/leaving temperature 23°C/18°C, fouling factor 0 m2 K/W. Condenser Water heat exchanger, entering/leaving temperature 30°C/35°C, fouling factor 0 m2 K/W. * In accordance with standard EN14511-3:2013 † Weight shown is a guideline only. The dimensions shown are for the standard unit. 2 Eurovent certified data Electrical data 30RB 580 630 810 880 AIR TREATMENT Fans 1150 Power circuit Nominal power supply ± 6% V-ph-Hz Control circuit supply 400-3-50 ± 10% A 75 95 118 118 176 Maximum operating power input** kW 7.8 9.1 11 13.8 17.5 Nominal unit operating current draw*** A 8 12 16 17 25 CONTROLS 24 V via internal transformer Maximum start-up current (Un)* * ** Maximum instantaneous start-up current (locked rotor current of the compressor). Power input, compressors and fans, at the unit operating limits (saturated suction temperature 10°C, saturated condensing temperature 65°C) and nominal voltage of 400 V (data given on the unit nameplate). *** Standardised Eurovent conditions: water heat exchanger entering/leaving water temperature 12°C/7°C, outside air temperature 35°C. C A R R I E R 2 0 1 6 / 2 0 1 7 51