AHI Carrier Catalog | Page 449

DUCTABLE AIR-COOLED SCROLL CHILLERS AND HEAT PUMPS 30PH / PHC Controls The 30PH control l is basically comprised of a µPC SMALL control board, a pGD1 graphic terminal, a TCO user terminal (optional for remote control) and sensors. This control allows the connection to a centralised technical management system by using a specific BMS card for some of the following communication protocols: Carel, Modbus, LonWorks®, BACnetTM MSTP, Konnex, M odbus TCP/IP, BACnetTM Ethernet, TCP/IP, SNMP V1-2-3, FTP and HTTP. ■■ pGD1 terminal ■■ Main functions: -- Control in HEATING mode. -- Selection of inlet water temperature setpoints for HEATING mode. -- Permanent control and optimization of the operating parameters -- Safety management. -- Timing of the compressor. -- Control of condensation and evaporation pressures. -- Control of outdoor electronic plug-fan (HEE version). -- Control of the circulation pump. -- Regulation of the water outlet temperature. -- Compensation of the setpoint based on the outdoor temperature. -- Timer and weekly programming. -- Failure diagnosis and main alarm. This graphic terminal, installed on the electric panel of the machine, allows: -- The initial programming of the unit -- Modification of operating parameters. -- Unit ON / OFF. -- Selection of the operating mode. -- Setting of setpoints. -- On-screen display of controlled variables and sensor values measured. -- On-screen display of active alarms and historical record of alarms. HEATING Cooling mode Heating mode Air 30PH/PHC AIR TREATMENT The TCO user terminal, for remote control, allows: -- Modification of some operating parameters. -- Unit ON / OFF. -- Selection of the operating mode and setting of setpoints. -- On-screen display some controlled variables and probe values. -- On-screen display of alarms codes. Operation limits Series ■■ TCO user terminal (optional for remote control): Water (outlet T.) Air Max. Min. Max. Min. Max. Min. Max. Water (outlet T.) Min. 46ºC 12ºC * 18ºC 5ºC ** 20ºC DB -15ºC DB 55ºC 30ºC +12 Mandatory glycol -10 0 +5 +18 Outlet water temp. in the evaporator °C A R R I E R 2 0 1 6 / +10 +0 -10 -15 C +20 CONTROLS Outdoor temperature °C DB +46 Condensation pressure control Outdoor temperature °C DB * With control of the condensation pressure operating up to -15ºC. ** Minimum outlet temperature. With the option of glycol water for lower temperature operation from 5ºC to -10ºC. 2 0 1 7 -15 +30 +45 +50 +55 Outlet water temp. in the condenser °C 449