AHI Carrier Catalog | Page 433

AIR-TO-WATER HEAT PUMPS  30RQ 017-040 Physical data 30RQ 017 021 026 033 040 Cooling Full load ­performances* C1 Nominal capacity kW 16.0 20.2 26.7 32.7 39.8 C1 EER kW/kW 3.17 3.11 3.01 3.21 2.92 C1 Eurovent Energy Class A A B A B C2 Nominal capacity kW 22.2 27.4 34.3 43.6 55 C2 EER kW/kW 4.02 3.76 3.62 3.96 3.5 ESEER kW/kW 3.61 3.44 3.36 3.58 3.25 H1 Nominal capacity kW 17.6 22.2 31.0 34.7 38.9 H1 COP kW/kW 3.99 3.98 3.98 3.98 3.51 H1 Eurovent Energy Class B B B B E H2 Nominal capacity kW 17 21.6 29.9 33.3 41 H2 COP kW/kW 3.18 3.28 3.2 3.19 3.16 H2 Eurovent Energy Class B A A B B H1 Energy Class A A A A A H1 SCOP kW/kW 3.03 3.05 3.11 3.13 3.14 Ƞs heat % 118 119 122 122 122 Prated KW 10 12 19 21 26 dB(A) 72 74 78 78 80 kg 206/191 223/208 280/262 295/277 304/287 Seasonal Efficiency* Full load performances* Seasonal Efficiency** Sound Power Level Standard Unit HEATING Heating Operating weight † Standard unit with/without hydronic module R-410A Compressor One hermetic scroll compressor Control Pro-Dialog+ Fans Two twin-speed axial fans, 3 blades One twin-speed axial fan, 7 blades 2217 3530 Air flow l/s 1978 3530 AIR TREATMENT Refrigerant 3530 Water heat exchanger Plate heat exchanger Air heat exchanger Copper tubes and aluminium fins Unit with hydronic module pump One single-speed pump, screen filter, expansion tank, flow switch, pressure gauge, automatic air purge valve, safety valve Entering water connection in 1-1/4 1-1/4 1-1/4 1-1/4 1-1/4 Leaving water connection in 1 1 1-1/4 1-1/4 1-1/4 Nominal operating current A 1.30 1.4 2.4 2.6 2.8 Length mm 1136 1136 1002 1002 1002 Depth mm 584 584 824 824 824 Height mm 1579 1579 1790 1790 1790 Dimensions Cooling mode conditions: Water heat exchanger, entering/leaving temperature 12°C/7°C, fouling factor 0 m K/W. Outside air temperature 35°C Cooling mode conditions::Water heat exchanger, entering/leaving temperature 23°C/18°C, fouling factor 0 m2 K/W. Outside air temperature 35°C Heating mode conditions: Water heat exchanger water entering/leaving temperature 30°C/35°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb, Heating mode conditions: Water heat exchanger water entering/leaving temperature 40°C/45°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb, In accordance with standard EN14511-3:2013 In accordance with standard EN14825:2013, average climate Weight shown is a guideline only. CONTROLS C1 C2 H1 H2 * ** † 2 Eurovent certified data Eurovent certified data C A R R I E R 2 0 1 6 / 2 0 1 7 433