AIR-TO-WATER HEAT PUMPS 30RQ 017-040
Physical data
30RQ
017
021
026
033
040
Cooling
Full load
performances*
C1
Nominal capacity
kW
16.0
20.2
26.7
32.7
39.8
C1
EER
kW/kW
3.17
3.11
3.01
3.21
2.92
C1
Eurovent Energy Class
A
A
B
A
B
C2
Nominal capacity
kW
22.2
27.4
34.3
43.6
55
C2
EER
kW/kW
4.02
3.76
3.62
3.96
3.5
ESEER
kW/kW
3.61
3.44
3.36
3.58
3.25
H1
Nominal capacity
kW
17.6
22.2
31.0
34.7
38.9
H1
COP
kW/kW
3.99
3.98
3.98
3.98
3.51
H1
Eurovent Energy Class
B
B
B
B
E
H2
Nominal capacity
kW
17
21.6
29.9
33.3
41
H2
COP
kW/kW
3.18
3.28
3.2
3.19
3.16
H2
Eurovent Energy Class
B
A
A
B
B
H1
Energy Class
A
A
A
A
A
H1
SCOP
kW/kW
3.03
3.05
3.11
3.13
3.14
Ƞs heat
%
118
119
122
122
122
Prated
KW
10
12
19
21
26
dB(A)
72
74
78
78
80
kg
206/191
223/208
280/262
295/277
304/287
Seasonal Efficiency*
Full load
performances*
Seasonal Efficiency**
Sound Power Level Standard Unit
HEATING
Heating
Operating weight
†
Standard unit with/without hydronic module
R-410A
Compressor
One hermetic scroll compressor
Control
Pro-Dialog+
Fans
Two twin-speed axial fans, 3 blades
One twin-speed axial fan,
7 blades
2217
3530
Air flow
l/s
1978
3530
AIR TREATMENT
Refrigerant
3530
Water heat exchanger
Plate heat exchanger
Air heat exchanger
Copper tubes and aluminium fins
Unit with hydronic module pump
One single-speed pump, screen filter, expansion tank, flow switch,
pressure gauge, automatic air purge valve, safety valve
Entering water connection
in
1-1/4
1-1/4
1-1/4
1-1/4
1-1/4
Leaving water connection
in
1
1
1-1/4
1-1/4
1-1/4
Nominal operating current
A
1.30
1.4
2.4
2.6
2.8
Length
mm
1136
1136
1002
1002
1002
Depth
mm
584
584
824
824
824
Height
mm
1579
1579
1790
1790
1790
Dimensions
Cooling mode conditions: Water heat exchanger, entering/leaving temperature 12°C/7°C, fouling factor 0 m K/W. Outside air temperature 35°C
Cooling mode conditions::Water heat exchanger, entering/leaving temperature 23°C/18°C, fouling factor 0 m2 K/W. Outside air temperature 35°C
Heating mode conditions: Water heat exchanger water entering/leaving temperature 30°C/35°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb,
Heating mode conditions: Water heat exchanger water entering/leaving temperature 40°C/45°C, fouling factor 0 m2 K/W. Outside air temperature 7°C db/6°C wb,
In accordance with standard EN14511-3:2013
In accordance with standard EN14825:2013, average climate
Weight shown is a guideline only.
CONTROLS
C1
C2
H1
H2
*
**
†
2
Eurovent certified data