AHI Carrier Catalog | Page 366

Accessories

Part No .
Description
Advantages
Use 38AW / 80AW
33AW-CS2
Additional user interface
Monitors two independent comfort zones or used together with
80AW 9025 & 80AWX or H
comfort module interface
33AW-CB01
Communication kit
Necessary when adding a user interface and keeping the one on
80AWX or H
comfort module
33AW-RAS02
Remote outdoor sensor
Positioned in the right place , the OAT sensor maximises comfort
80AWX or H
compared to using the condensing unit OAT sensor .
33AW-RRS01
Room temperature sensor
Monitors indoor climate if user interface is left on indoor unit , or if
80AW 9025 & 80AWX or H
two zones are covered and only one user interface is installed .
60STS020E03
Domestic hot water tank , 1 coil - 200 l
Storage , 200 l of domestic hot water
80AW 9025 & 80AWX or H
60STS030E03 Domestic hot water tank , 1 coil - 300 l Storage , 300 l of domestic hot water 80AW 9025 & 80AWX or H
60STD020E03
Domestic hot water tank , 2 coils - 200 l
Storage , 200 l of domestic hot water with thermal solar panel
80AW 9025 & 80AWX or H
connection
60STD030E03
Domestic hot water tank , 2 coils - 300 l
Storage , 300 l of domestic hot water with thermal solar panel
80AW 9025 & 80AWX or H
connection
80AW9017
CDU rubber vibration isolators
Reduce the noise and vibration of the unit .
38AW
80AW9023
Domestic hot-water three-way valve and
Necessary to connect domestic hot water tank .
80AWX or H
actuator
80AW9024
Thermal cut-out , floor heating
Necessary when connecting under-floor heating zone
80AWX or H
80AW9025 Two-zone kit Allows independent control of two comfort zones 80AWX or H
HEATING
80AW9026
80AW9027

Features and advantages

Features
Piping kit to install domestic hot-water valve and actuator ( 80AW9023 ) inside the unit
Cover panel to install two-zone kit ( 80AW9025 ) detached from comfort module
■■
Wide operating range in both heating and cooling mode offers high performance in a wide temperature range .
■■
DC inverter twin-rotary compressors with Pulse Amplitude Modulation ( PAM ) and Pulse Width Modulation ( PWM ) provide enhanced reliability , low energy consumption and smooth vibration-free operation under all operating conditions .
■■
Variable-speed fans with an innovative patented fan blade shape ensure improved air distribution at exceptionally low noise levels .
■■
Pre-set or customised selection of the appropriate climate curve for stable output capacity to match the heat load .
■■
Output to link and integrate the unit with the existing heat sources offers a dual-energy approach , increased savings and optimum comfort in all weather conditions .
■■
Able to control two independent comfort zones with a two-zone kit added to the main comfort module .
■■
Leaving water temperature up to 60 ° C for radiator and domestic hot water applications , making hot water readily available .
Ecodesign is the European Directive that sets mandatory requirements for Energy related Products ( ErP ) to improve their energy efficiency . Carrier supports initiatives to reduce the environmental impact of its products .
Specific DHW piping kit for the installation , used together with 80AW9025
Hides piping and connections , if two-zone kit is installed remotely from the main comfort module .
80AW 9025 & 80AWX or H
80AW 9025 & 80AWX or H
80AW9028 Additional 3-way valve kit Possibility to have a 3-way valve also on the 2nd zone circuit 80AW 9025 & 80AWX or H
Adapted to your needs
■■ Heating only or reversible comfort module
■■
Backup heating , either electrical ( single-energy applications ) or gas boiler ( dual-energy applications )
■■
Comfort is ensured via the user interface and the possibility of integrating two leaving water temperature zones .
Advanced technology
■■
Electronic system management : several sensors placed in key positions in the refrigerant circuit electronically detect the operational system status . Two microcontrollers receive the input from the sensors , manage them using advanced control algorithms and optimise the refrigerant flow and the functioning of all the core components - the compressor , fan motors and the pulse modulation valve .
■■
The pulse modulation valve , a bi-flow electronic expansion device , optimises the refrigerant amount in the circuit and the superheat , and prevents the refrigerant migration back into the compressor . This device further enhances high system performance and reliability .
■■
The air management system , which consists of a propeller fan , orifice and an air discharge grille , guarantees minimised noise levels .
366