Options No . Description Advantages Use 30XW
COOLING
Control for low condensing temperature systems
Energy Management Module EMM
Touch Pilot control , 7 ” user interface
152 Output signal ( 0-10 V ) to control the condenser water inlet valve
156 Control board with additional inputs / outputs . See Energy Management Module option chapter
158A
Touch Pilot control supplied with a 7 inch colour touch screen user interface
Leak detection
159
0-10 V signal to report any refrigerant leakage in
the unit directly on the controlller ( the leak detector
itself must be supplied by the customer )
Compliance with Swiss regulations
197 Additional tests on the water heat exchangers : supply ( additional of PED documents ) supplementary certificates and test certifications
Simple installation : for applications with cold 254-1762 water at condenser inlet ( ex . ground-source , groundwater-source , superficial water-source applications ) the signal permits to control a 2 or 3-way valve to maintain condenser water temperature ( and so condensing pressure ) at acceptable values
Extended remote control capabilities ( Set-point 254-1762 reset , ice storage end , demand limits , boiler on / off command ...)
Enhanced ease of use 254-1762
Immediate customer notification of refrigerant 254-1762 losses to the atmosphere , allowing timely corrective actions
Conformance with Swiss regulations 254-1762
Compliance with Australian
200
Unit approved to Australian code
Conformance with Australian regulations
254-1762
regulations
Low noise level
257
Evaporator and suction piping sound insulation
3 dB ( A ) quiter than standard unit
254-1762
Welded evaporator water
266
Victaulic piping connections with welded joints
Easy installation
254-1762
connection kit
Welded condenser water
267
Victaulic piping connections with welded joints
Easy installation
254-1762
connection kit
Flanged evaporator water
268
Victaulic piping connections with flanged joints
Easy installation
254-1762
connection kit
Flanged condenser water connection kit
269
Victaulic piping connections with flanged joints
Easy installation
254-1762
Thermal compressor insulation
271
The compressor is covered with a thermal insulation layer
230V electrical plug
284
230V AC power supply source provided with plug
socket and transformer ( 180 VA , 0,8 Amps )
Carrier Connect link ( BSS regions only )
298 3G router board NOTE 1 : require option 149 NOTE 2 : when more than one machine is installed on site , only one of them shall be equipped with option 298 while all of them must be equipped with option 149 NOTE 3 : if a CARRIER-PSM is on site , option 298 shall be integrated in the PSM while option 149 is still mandatory for each single unit .
Prevents air humidity to condensate on the 254-1762 compressor surface
Permits connection of a laptop or an electrical 254-1762 device during unit commissioning or servicing
Enabler for Carrier Connect service offer 254-1762

Accessories

Accessories Description Advantages Use 30XW
Very low noise level ( -20 dB ( A ) compared to standard unit )
Very low noise level ( -20 dB ( A ) compared to standard unit )
Sound absorbing cabinet for single-circuit units
Sound absorbing cabinet for twin-circuit units
Significantly quieter ( -20 dB ( A )) than a unit without this option
Significantly quieter ( -20 dB ( A )) than a unit without this option
254-862
1002-1252 , 1352 , 1452 , 1552 , 1314 , 1464
Remote management ( EMM option )
The Energy Management Module offers extended remote
--
User safety : this contact can be used for any
control possibilities :
customer safety loop ; opening of the contact
--
--
--
--
254
Room temperature : permits set-point reset based on the building indoor air temperature ( with Carrier thermostat )
Set point reset : ensures reset of the cooling set-point based on a 4 – 20 mA or 0 – 10 V signal
Demand limit : permits limitation of the maximum chiller power or current based on a 0 – 10 V signal
Demand limit 1 and 2 : closing of these contacts limits the maximum chiller power or current to two predefined values
--
--
--
--
generates a specific alarm
Ice storage end : when ice storage has finished , this input permits return to the second set-point
( unoccupied mode )
Time schedule override : closing of this contact cancels the time schedule effects
Out of service : this signal indicates that the chiller is completely out of service
Chiller capacity : this analogue output ( 0 – 10 V ) gives an immediate indication of the chiller capacity