WATER-COOLED LIQUID CHILLERS  30XW 254-1762 Physical data Standard-efficiency units 30XW-- 254 304 354 402 452 552 602 652 702 802 Cooling Air conditioning application as per EN14511-3:2013† - standard unit Nominal cooling capacity kW 273 307 359 459 473 532 538 677 730 792 ESEER kW/kW 5.67 5.58 5.58 5.75 5.77 5.78 5.66 6.06 6.02 5.79 EER kW/kW 5.32 5.30 5.24 5.21 5.35 5.21 5.17 5.39 5.30 5.19 Eurovent class cooling - A A A A A A A A A A Air conditioning application †† - standard unit Condition 1 Nominal cooling capacity kW 273 308 360 461 474 534 539 679 733 795 ESEER kW/kW 6.18 6.09 6.14 6.28 6.29 6.46 6.33 6.76 6.79 6.63 EER kW/kW 5.54 5.52 5.48 5.42 5.57 5.46 5.43 5.65 5.58 5.50 Sound power level* dB(A) 95 95 95 99 99 99 99 99 99 99 Sound pressure level at 1 m** dB(A) 78 78 78 82 82 82 82 82 82 82 COOLING Condition 1 Sound levels - standard unit Sound levels - standard unit + option 257*** Sound power level* dB(A) - - - 96 96 96 96 96 96 96 Sound pressure level at 1 m** dB(A) - - - 78 78 78 78 78 78 78 Length mm 2724 2724 2724 2741 2741 2741 2741 3059 3059 3059 Width mm 928 928 928 936 936 936 936 1040 1040 1040 Height mm 1567 1567 1567 1692 1692 1692 1692 1848 1848 1848 Operating weight**** kg 2017 2036 2072 2575 2575 2613 2644 3247 3266 3282 Compressors Semi-hermetic 06T screw compressors, 50 r/s Circuit A - 1 1 1 1 1 1 1 1 1 1 Circuit B - - - - - - - - - - - Refrigerant**** - standard unit R-134a Circuit A kg 84 80 78 82 82 82 82 145 140 135 Circuit B kg - - - - - - - - - - tonnes 120 114 112 117 117 117 117 207 200 193 Global Warming Potential (GWP) Tonnes of equivalent CO2 of greatest circuit Capacity control Touch Pilot, electronic expansion valves (EXV) Minimum capcity % 15 Evaporator 15 15 15 15 15 15 15 15 15 HEATING HEATING Dimensions - standard unit Water volume l 50 56 61 70 70 70 70 109 109 109 Water connections (Victaulic) in 5 5 5 5 5 5 5 6 6 6 Drain and vent connections (NPT) in 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Max. water-side operating pressure kPa 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 Condenser Multi-pipe flooded type Water volume l 55 55 55 76 76 76 76 109 109 109 Water connections (Victaulic) in 5 5 5 5 5 5 5 6 6 6 Drain and vent connections (NPT) in 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Max. water-side operating pressure kPa 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 † Eurovent-certified performances in accordance with standard EN14511-3:2013. † † Gross performances, not in accordance with EN14511-3:2013. These performances do not take into account the correction for the proportional heating capacity and power input generated by the water pump to overcome the internal pressure drop in the heat exchanger. Condition 1 : Cooling mode conditions, evaporator water entering/leaving temperature 12°C/7°C, condenser water entering/leaving temperature 30°C/35°C, evaporator fouling factor 0 m².K/W. Condition 2: Cooling mode conditions, condenser water entering/leaving temperature 40°C/45°C, evaporator water entering/leaving temperature 10°C/7°C, evaporator fouling factor 0 m².K/W. * In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured in accordance with ISO 9614-1 and certified by Eurovent. ** In dB ref 20µPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). For information, calculated from the sound power level Lw(A). *** Option 257 = Low noise level. **** Weight shown is guideline only. Please refer to the unit nameplate. AIR TREATMENT Multi-pipe flooded type CONTROLS Eurovent certified data C A R R I E R 2 0 1 6 / 2 0 1 7 249