Low-temperature brine solution |
6 |
Low-temperature glycol solution production down |
to -10 ° C |
IP44C electrical protection level |
20 |
Control box tightness reinforced |
Permits unit installation in more severe environments |
|
Tropicalisation |
22 |
Unit control box suitable for tropical climates |
Reduced relative humidity in the control boxes for
080-375
|
|
operation in tropical climates ( warm and humid ) |
||||
Soft starter |
25 |
Electronic compressor starter |
Reduced compressor start-up current |
200-375 |
Cu / Ni condensers |
33 |
Condenser tubes and tubes sheets in 90-10 |
Allows applications with sea water |
080-375 |
Copper / Nickel alloy |
||||
Cu / Ni condensers + Sakaphen |
34A |
Condenser tubes and tubes sheets in 90-10 |
Allows applications with sea water , improved |
080-375 |
coated water boxes |
Copper / Nickel alloy and Sakaphen treatment inside durability of water boxes |
water boxes |
||
51 |
Unit supplied in two assembled parts . The unit is |
Facilitates installation in plant rooms with limited |
equipped with flanges that allow disassembly of the access | ||
unit on site . |
460-3-60 power supply |
60 |
Power supply of 460 V-3 ph-60 Hz |
Permits unit connection to a power network with
080-375
|
|
specific characteristics |
||||
380-3-60 power supply |
61 |
Power supply of 380 V-3 ph-60 Hz |
Permits unit connection to a power network with
080-375 specific characteristics
|
|
Evaporator pump electrical power /
84
|
Unit equipped with an electrical power / control |
Quick and easy installation |
080-375 |
|
control circuit |
circuit for single evaporator pumps |
|||
Dual evaporator pump electrical power / control circuit |
84D |
Unit equipped with an electrical power / control circuit for dual evaporator pumps |
Quick and easy installation |
080-375 |
Condenser pump electrical power /
84R
|
Unit equipped with an electrical power / control |
Quick and easy installation |
080-375 |
|
control circuit |
circuit for single condenser pumps |
|||
Compressor suction valve |
92 |
Valve set for the compressor suction side to isolate it
Simplified service and maintenance
|
080-375 |
|
in the refrigerant circuit . |
||||
Evaporator with one pass |
100C |
Evaporator with one pass on the water-side . Evaporator inlet and outlet on opposite sides . |
Quick and easy installation . Reduced evaporator
080-375 pressure losses .
|
|
Condenser with one pass |
102C |
Condenser with one pass on the water-side . |
Quick and easy installation . Reduced condenser |
080-375 |
Condenser inlet and outlet on opposite sides . |
pressure losses . |
|||
21 bar evaporator |
104 |
Reinforced evaporator for extension of the |
Covers applications with a high water column |
080-375 |
maximum water-side service pressure to 21 bar |
( high buildings ) |
|||
21 bar condenser |
104A |
Reinforced condenser for extension of the |
Covers applications with a high water column |
080-375 |
maximum water-side service pressure to 21 bar |
( high buildings ) |
|||
Reversed evaporator water |
107 |
Evaporator with reversed water inlet / outlet |
Simplification of the water piping |
080-375 |
connections |
||||
Reversed condenser water |
107A |
Condenser with reversed water inlet / outlet |
Simplification of the water piping |
080-375 |
connections |
||||
JBus / ModBus gateway |
148B |
Two-directional communications board , complies |
Easy connection by communication bus to a |
080-375 |
with JBus / ModBus protocol |
building management system |
|||
BacNet gateway |
148C |
Two-directional communications board , complies |
Easy connection by communication bus to a |
080-375 |
with BacNet protocol |
building management system |
|||
LON gateway |
148D |
Two-directional communications board , complies |
Easy connection by communication bus to a |
080-375 |
with LON protocol |
building management system |
|||
High condensing temperature |
150 |
Increased condenser leaving water tempe-rature up to 63 ° C . Control of the condenser leaving water |
Allows applications with high condensing temperature ( for heat reclaim or dry cooler |
080-375 |
temperature . |
applications ) |
|||
150A |
Operation in heat pump mode only with condenser
Allows applications with high condensing
|
080-375 |
||
leaving water temperature up to 63 ° C . |
temperature ( for heat reclaim or dry cooler |
|||
applications ) |
||||
152 |
Output signal ( 0-10 V ) to control the condenser |
Used for applications with cold water at |
080-375 |
|
water inlet valve |
condenser inlet ( well water ). In this case the valve |
|||
controls the water entering temp . to maintain an |
||||
acceptable condensing pressure . |
||||
155 |
Additional RS 485 communication board |
Communication via CCN protocol |
080-375 |
standard EN 378 / BGVD4 . |
||
197 |
Additional tests on the water heat exchangers . |
Conformance with Swiss regulations in addition |
Additional supply of PED documents , supple-mentary to the PED code | ||
certificates and test certificates . |
Russian code compliance |
199 |
GOST certification |
Conformance with Russian regulations ( GOST ) |
080-375 |
Water connection kit for welded |
266 |
Victaulic piping connections with welded joints . |
Easy installation |
080-375 |
evaporator connections |
||||
Water connection kit for welded |
267 |
Victaulic piping connections with welded joints . |
Easy installation |
080-375 |
condenser connections |
||||
Water connection kit for flanged |
268 |
Victaulic piping connections with flanged joints . |
Easy installation |
080-375 |
evaporator connections |
||||
Water connection kit for flanged
condenser connections
|
269 |
Victaulic piping connections with flanged joints . |
Easy installation |
080-375 |