AHI Carrier Catalog | Page 235

WATER-COOLED/CONDENSERLESS LIQUID CHILLERS WITH INTEGRATED HYDRONIC MODULE 30RW/30RWA 110-300 Physical data 30RW/RWA 110 120 135 150 160 185 210 245 275 300 kW 109.6 kW/kW 4.05 D kW/kW 4.79 124.52 3.90 D 4.56 141.48 4.00 D 4.74 151.49 3.92 D 4.66 164.45 4.49 C 5.36 186.36 4.25 D 5.06 219.43 4.35 C 5.17 251.27 4.28 C 5.01 288.28 4.32 C 5.27 315.1 4.31 C 5.15 kg kg 864 773 937 836 956 845 977 855 1079 948 1144 996 1357 1159 1471 1273 1557 1311 1557 1311 kg kg kg kg kg 15 15 130 80 140 15 15 130 80 140 15 15 130 80 140 15 15 130 80 140 245 245 300 250 310 245 245 300 250 310 245 245 358 265 368 245 285 358 265 368 245 285 358 265 368 245 285 358 265 368 mm mm 2013 x 922 x 1963 2950 x 922 x 1993 R-407C Hermetic scroll, 48.3 r/s Pro-Dialog Plus Welded plate heat exchangers, max. water-side operating pressure with hydronic module 1000 kPa, without hydronic module 400 kPa Removable screen filter, variable-speed water pump, expansion tank, safety valve, pressure gauge, and purge valve Single or twin-head composite centrifugal pump, according to option used, variable speed by frequency converter (48.3 r/s) Welded direct-expansion plate heat exchanger, max. water-side operating pressure with hydronic module 1000 kPa, without hydronic module 400 kPa Removable screen filter, water pump, expansion tank, water flow switch, safety valve, pressure gauge, purge valve and control valve Single or twin-head composite centrifugal pump, according to option used (48.3 r/s) Victaulic*** Welded copper tube Seasonal Efficiency* Operating weight 30RW unit without pump 30RWA unit without pump Extra weight 30RW: single evaporator pump (option 116B) 30RWA: single evaporator pump (option 116B) 30RW/RWA: dual evaporator pump (option 116C) 30RW: single condenser pump (option 270B) 30RW: dual condenser pump (option 270C) Dimensions (length x depth x height) Standard unit with or without hydronic module Unit with hydronic module (options 116B, 116C, 270B, 270C) Refrigerant** 30RW Compressors 30RW/30RWA Control Condensers (30RW) Hydronic condenser module (30RW) Condenser pump Evaporator (30RW/30RWA) Hydronic evaporator module (30RW/30RWA) Evaporator pump Water connections (30RW/30RWA) Field refrigerant connections (30RWA) C1 Cooling mode conditions: Evaporator Water heat exchanger, entering/leaving temperature 12°C/7°C, fouling factor 0 m2 K/W. Condenser Water heat exchanger, entering/leaving temperature 30°C/35°C, fouling factor 0 m2 K/W. * In accordance with standard EN14511-3:2013 † Weight shown is a guideline only. The dimensions shown are for the standard unit. For other unit types please refer to the dimensional drawings. ** The RWA units only have a nitrogen holding charge. *** With tubular sleeve, supplied with the unit, consisting of a Victaulic connection at one end and a plain section at the other end. Eurovent certified data Electrical data 30RW/RWA (without hydronic module) 110 120 Power circuit Nominal power supply V-ph-Hz 400-3-50 ± 10% Control circuit supply Maximum unit power input, 30RW + 30RWA* kW *** † ‡ C 150 24 V via internal transformer 42.4 48.8 54.0 59.1 Nominal unit current draw 30RW** A 48.1 Nominal unit current draw 30RWA*** A 51.4 Ma ximum start-up current, (standard unit without electronic starter) A 245.2 30RW + 30RWA† Maximum start-up current, (electronic-starter option) A 159.2 30RW + 30RWA‡ * ** 135 160 185 210 245 275 300 63.2 72.2 84.9 97.6 107.9 118.2 54.0 58.0 61.0 64.7 68.0 71.4 71.7 76.3 84.2 89.6 96.1 102.8 108.0 116.0 122.0 129.4 136.0 142.8 254.0 309.0 318.0 212.6 245.7 314.5 332.0 396.0 414.0 168.0 201.0 210.0 158.6 183.7 228.5 246.0 288.0 306.0 Power input of the compressor(s) at maximum unit operating conditions: entering/leaving evaporator water temp. 15°C/10°C, maximum condensing temp. 65°C, and 400 V nominal voltage. Nom. unit current draw at standard conditions: evaporator entering/leaving water temp. 12°C/7°C, condenser entering/leaving water temp. 30°C/35°C. The current values are given at 400 V nom. voltage. Nom. unit current draw at standard conditions: evaporator entering/leaving water temp. 12°C/7°C, saturated condensing temp. (dew point) 45°C, subcooling 5 K. The current values are given at 400 V nom. voltage. Max. instantaneous starting current at 400 V nom. voltage and with compressor in across-the-line start (max. operating current of the smallest compressor(s) + locked rotor current of the largest compressor). Max. instantaneous starting current at 400 V nom. voltage and with compressor with electronic starter (max. operating current of the smallest compressor(s) + reduced start-up current of the largest compressor). A R R I E R 2 0 1 6 / 2 0 1 7 235 HEATING HEATING Nominal capacity EER Eurovent Energy Class ESEER AIR TREATMENT C1 C1 C1 CONTROLS 30RW Full load performances* COOLING Cooling