AHI Carrier Catalog | Page 221

WATER-COOLED/CONDENSERLESS LIQUID CHILLERS 30WG/30WGA 020-090 Hydronic module (options 116T, 270T) Typical water piping diagram 2 PT Unit water inlet 3 6 4 5 TT 7 15 Components of unit and hydronic module 9 1 Victaulic screen filter (option 293 or 293A only) 2 Expansion tank (option 293 or 293A only) 3 Safety valve (option 293 or 293A only) 4 Water pump 5 Air vent 6 Water drain valve 7/8 Entering/leaving pressure sensor 9/10 Entering/leaving temperature probe 12 Flow switch 61WG option 272 (sizes 020-045 only) 13 Compressor 14 Evaporator 15 Condenser 16 Expansion device Condenser water loop (30WG) TT PT 10 8 Unit water outlet 2 1 PT Unit water inlet 6 3 4 6 5 13 TT 16 14 9 7 COOLING 1 NOTE: Units without hydronic module include a flow switch. Evaporator water loop (30WG/30WGA) Unit water outlet 12 TT PT 10 8 6 020 025 030 035 040 045 050 060 070 080 090 Operating weight, 30WG/61WG (options 116V and 270V)* Operating weight, 30WGA (option 116V)* Height** Hydronic module Maximum operating pressure Water filter (max. removed particle diameter) Expansion tank capacity*** Water connections * ** *** kg kg mm 305 250 1463 313 258 1463 313 258 1463 321 263 1463 327 266 1463 334 271 1463 513 431 1463 521 435 1463 533 442 1463 544 449 1463 574 465 1463 kPa mm l in 300 1.2 8 1.5 300 1.2 8 1.5 300 1.2 8 1.5 300 1.2 8 1.5 300 1.2 8 1.5 300 1.2 8 1.5 300 1.2 12 2 300 1.2 12 2 300 1.2 12 2 300 1.2 12 2 300 1.2 12 2 Weight shown is a guideline only. The length and width dimensions are the same as for the standard unit. When delivered, the standard pre-inflation of the tanks is not necessary the optimal value for the system. To permit changing the water volume, change the inflation pressure to a pressure that is close to the static head of the system. Fill the system with water (purging the air) to a pressure value that is 10 to 20 kPa higher than the pressure in the tank. Electrical data, options 116T, 270T The original pumps that are factory-installed in these units have motors with efficiency class IE2. The additional electrical data required by regulation 640/2009 are given in the installation, operation and maintenance instructions. This regulation regards the application of directive 2005/32/ CE on the eco-design requirements for electric motors. Pump curve, 30WG/30WGA (options 116, 270) Data applicable for: -- Fresh water 20 °C -- In case of use of the glycol, the maximum water flow is reduced -- T he curves represented below are in normal conditions: leaving water on the back side of the unit (without option 274). Variable-speed high-pressure pumps (options 116V - 270V) Fixed-speed low-pressure pumps (options 116T - 270T) 220 30WG-30WGA 020-080 30WG-30WGA 090 200 Pressure head, kPa Pressure head, kPa 2 1 3 4 4 180 30WG-30WGA 020-045 30WG-30WGA 050-090 160 3 140 CONTROLS 1 2 120 100 80 60 40 20 0 0 C A R R I E Water flow rate, l/s R 2 0 1 6 / 1 2 3 4 5 6 7 8 Water flow rate, l/s 2 0 1 7 AIR TREATMENT 30WG/30WGA HEATING HEATING Physical data, units with hydronic module 9 10 11 12 221