AHI Carrier Catalog | Page 197

AIR-COOLED LIQUID CHILLERS  30XAV 500-1150 Physical data 30XAV 500 600 700 800 950 1050 1150 910 4.72 3.12 A 1041 4.68 3.08 B 1138 4.84 3.1 A 912 4.94 3.16 5.33 1044 4.91 3.12 5.29 1141 5.05 3.14 5.50 105 72 106 73 106 73 102 69 103 70 103 70 99 66 100 67 100 67 9573 2253 2297 10767 2253 2297 11962 2253 2297 Circuit B Capacity control Minimum capacity Condensers Fans - Standard unit Quantity Total air flow Rotation speed Evaporator Water content Max. water-side operating pressure Water connection Diameter Outside tube diameter Chassis paint colour 4831 5219 5767 6420 6806 7687 8076 1 1 1 1 1 1 1 1 1 1 1 1 1 1 64 91.5 67 95.8 79 113.0 71 101.5 80 114.4 82 117.3 84 120.1 87 124.4 10 10 10 10 14 63168 15.7 16 72192 15.7 18 81216 15.7 20 90240 15.7 110 1000 120 1000 134 1000 146 1000 6 168.3 6 168.3 8 219.1 8 219.1 R134a kg 50 52 56 71.5 74.4 80.1 teqCO2 kg 43 54 58 61.5 77.2 82.9 teqCO2 Touch Pilot control % 10 10 10 “Micro Channel Heat Exchanger" aluminium coil Axial Flying Bird IV fans with rotating shroud 9 10 12 40608 45120 54144 r/s 15.7 15.7 15.7 Flooded multi-pipe type l 75 90 90 1000 1000 1000 Victaulic inch 5 6 6 mm 141.3 168.3 168.3 Colour code: RAL7035 HEATING HEATING kg AIR TREATMENT Operating Weight ** Standard unit Compressors Circuit A Circuit B Refrigerant** - Standard unit Circuit A † Eurovent-certified performances in accordance with standard EN14511-3:2013. Cooling mode conditions: Evaporator water entering/leaving temperature 12 °C/7 °C, outside air temperature 35 °C. evaporator fouling factor 0 m2 k/W †† Gross performances, not in accordance with EN14511-3:2013. These performances do not take into account the correction for the proportional heating capacity and power input generated by the water pump to overcome the internal pressure drop in the heat exchanger. Evaporator water entering/leaving temperature 12 °C/7 °C, outside air temperature 35 °C. evaporator fouling factor 0 m2 k/W * Options: 257 = low noise level, 279 = compressor enclosure. ** Weights are guidelines only. Refer to the unit nameplate. *** In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3 dB(A)). Measured in accordance with ISO 9614-1 and certified by Eurovent. **** In dB ref 20µPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3 dB(A)). For information, calculated from the sound power level Lw(A). Eurovent certified data C A R R I E R 2 0 1 6 / 2 0 1 7 197 CONTROLS Air conditioning application as per EN14511-3:2013† - standard unit with option 279* Nominal cooling capacity kW 504 607 687 803 ESEER kW/ kW 4.59 4.67 4.79 4.90 EER kW/ kW 3.22 3.23 3.29 3.28 Eurovent class cooling A A A A Air conditioning application†† - standard unit with option 279* Nominal cooling capacity kW 506 609 689 806 ESEER kW/ kW 4.88 4.97 5.16 5.15 EER kW/ kW 3.25 3.26 3.34 3.32 IPLV kW/ kW 5.20 5.21 5.51 5.57 Sound levels Standard unit Sound power level*** dB(A) 102 103 103 103 Sound pressure level at 10 m**** dB(A) 70 70 70 70 Standard unit + option 279* Sound power level*** dB(A) 99 100 100 100 Sound pressure level at 10 m**** dB(A) 67 68 68 67 Standard unit + option 257* Sound power level*** dB(A) 96 97 97 97 Sound pressure level at 10 m**** dB(A) 63 65 64 64 Dimensions - standard unit Length mm 6092 6092 7186 8380 Width mm 2253 2253 2253 2253 Height mm 2297 2297 2297 2297 COOLING Cooling