AIR-COOLED LIQUID CHILLERS 30XA 252-1702
Options
Use for 30XA
range
Options
No.
Description
Advantages
Corrosion protection,
traditional coils
Corrosion protection,
traditional coils
Medium-temperature
brine solution
2B
Improved corrosion resistance, recommended for
industrial, rural and marine environments
Improved corrosion resistance, recommended for
moderate marine and urban environments
Covers specific applications such as ice storage
and industrial processes
252-1702*
Low-temperature brine
solution
6
Covers specific applications such as ice storage
and industrial processes
252-1702*
Unit equipped for air
discharge ducting
IP54 control box
10
Factory application of Blygold Polual treatment on
the copper/aluminium coils
Fins made of pre-treated aluminium (polyurethane
and epoxy)
Implementation of new algorithms of control and
evaporator redesign to allow chilled brine solution
production down to -6 °C when ethylene glycol is
used (-3 °C with propylene glycol)
Implementation of new algorithms of control and
evaporator redesign to allow chilled brine solution
production down to -12 °C when ethylene glycol
is used (-8 °C with propylene glycol)
Fans equipped with discharge connection flanges
- maximum available pressure 60 kPa
Increased leak tightness of control boxes
Facilitates connections to the discharge ducts
252-1702*
Tropicalisation of the
electrical box
22
Grilles and enclosure
panels
23
Enclosure panels
23A
Winter operation down
to -20 °C
Evaporator frost
protection
Evap.and hydraulic mod.
frost protection
Total heat recovery
28
Master/slave operation
58
Single power connection
point
Service valve set
81
41A
41B
50
92
Compressor discharge
93A
valves
Evaporator with one pass 100A
more
Evaporator with one pass 100C
less
21 bar evaporator
104
Reversed evaporator
107
water connections
HP single-pump hydronic 116B
module
HP dual-pump hydronic
module
116C
LP single-pump hydronic
module
116F
LP dual-pump hydronic
module
116G
*
**
C
252-1702
Evaporator with one pass more on the water side
Optimise chiller operation when the chilled water
circuit is designed with low waterflows (high delta
T evaporator inlet/oulet)
Easy to install, depending on site. Reduced
pressure drops
Covers applications with a high water column
evaporator side (typically high buildings)
252-1702
Easy installation on sites with specific
requirements
Complete hydronic module equipped with water filter, Plug & play approach
expansion tank with relief valve, one high pressure
pump, drain valve and water flow control valve. For
more details, refer to the dedicated chapter
Complete hydronic module equipped with
Plug & play approach. Increased system reliability
water filter, expansion tank with relief valve, two
high pressure pumps, drain valve and water
flow control valve. For more details, refer to the
dedicated chapter
Complete hydronic module equipped with water filter, Plug & play approach
expansion tank with relief valve, one low pressure
pump, drain valve and water flow control valve. For
more details, refer to the dedicated chapter
Complete hydronic module equipped with water
Plug & play approach. Increased system reliability
filter, expansion tank with relief valve, two low
pressure pumps, drain valve and water flow
control valve. For more details, refer to the
dedicated chapter
252-1702
Evaporator with one pass on the water side.
Evaporator inlet and outlet on opposite sides.
Reinforced evaporator for extension of the
maximum water-side service pressure to 21 bar
(standard 10 bar)
Evaporator with reversed water inlet/outlet
COOLING
Protects the inside of the electrical box from dusts
and sand. In general this option is recommended
for installations in polluted environments
Electrical box equipped with an electrical
Grant safe operation in typical "tropical" climate.
heater and a fan. Electrical connections on the
This option is recommended for all applications
compressors painted with a special varnish and
where humidy inside the electrical box can reach
covered with an anti-condensation foam.
80% at 40 °C and unit can remain in stand-by for
a long time under this conditions.
Metal grilles on the 4 unit sides, plus side
Improves aesthetics, protection against intrusion
enclosure panels at each end of the coil
to the unit interior, coil and piping protection
against impacts.
Side enclosure panels at each end of the coil
Improves aesthetics, coil and piping protection
against impacts.
Fan speed control via frequency converter
Stable unit operation for air temperature down to
-20 °C
Electric resistance heater on the evaporator and
Evaporator frost protection down to -20 °C
discharge valve
outside temperature
Electric resistance heater on evaporator, discharge Evaporator and hydronic module frost protection
valve and hydronic module
down to -20 °C outside temperature
Unit equipped with additional heat exchanger in
Production of free hot-water simultaneously with
parallel with the condenser coils.
chilled water production
Unit equipped with supplementary water outlet
Optimised operation of two chillers connected in
temperature sensor kit to be field-installed
parallel with operating time equalisation
allowing master/slave operation of two units
connected in parallel
Quick and easy installation
Unit power connection via one main supply
connection
Allow isolation of various refrigerant circuit
Liquid line valve (evaporator inlet), compressor
suction and discharge line valves and economiser components for simplified service and
line valve
maintenance
Shut-off valve on the compressor discharge piping Simplified maintenance
252-1702
252-1702
252-1702
252-1702
252-1702
HEATING HEATING
20A
252-1702*
252-1702
252-1702*
252-1702
1112-1502
252-1702
252-1702
AIR TREATMENT
5
252-1702*
252-1002
252-1702
252-1702**
252-1702**
252-1702**
CONTROLS
3A
252-1702**
Not available for the sizes 504, 854, 904.
Not available for the size 504.
A
R
R
I
E
R
2
0
1
6
/
2
0
1
7
179