AHI Carrier Catalog | Page 149

AIR-COOLED LIQUID CHILLERS WITH INTEGRATED HYDRONIC MODULE 30RB 602-802 Physical data 30RB units 602 672 732 802 Cooling Full load performances* C1 Nominal capacity kW 606.9 657.3 711.8 774.4 C1 EER kW/kW 2.72 2.68 2.59 2.58 C1 Eurovent Energy Class C D D D kW/kW 3.97 3.88 3.75 3.71 Sound Power Level Standard Unit dB(A) 95 95 96 96 Sound Power Level Standard Unit + Option 15 dB(A) 93 93 94 94 Seasonal ESEER COOLING Efficiency* Full load performances* C1 Nominal capacity kW 561.2 631.3 670.2 721.4 C1 EER kW/kW 2.43 2.45 2.44 2.42 C1 Eurovent Energy Class E E E E kW/kW 4.06 4.06 4.08 4.00 Sound Power Level Standard Unit + Options 15LS dB(A) 89 89 89 90 Operating weight - standard unit† kg 4627 4873 5362 5609 Seasonal Efficiency* ESEER Compressors Hermetic scroll, 48.3 r/s Refrigerant R-410A Capacity control Pro-Dialog Plus Condensers All aluminium micro-channel heat exchanger (MCHE) Fans Axial Flying Bird 4 with rotating shroud Quantity Total air flow (high speed) l/s Evaporator 9 10 11 12 40623 45139 49653 54167 HEATING HEATING Unit with Option 15LS Direct expansion, shell-and-tube Dimensions Length mm 5992 7186 Depth mm 2253 2253 Height mm 2297 2297 AIR TREATMENT C1 Cooling mode conditions: Water heat exchanger, entering/leaving temperature 12°C/7°C, fouling factor 0 m2 K/W. Outside air temperature 35°C * In accordance with standard EN14511-3:2013 † Weight shown is a guideline only. Eurovent certified data Option 15 = compressor enclosure Option 15LS = low sound option For 30RB 162-262 units with option 280 (shell-an d-tube heat exchanger) please refer to the specific product literature Electrical data 30RB (without hydronic module) 602 672 732 802 Power circuit Nominal power supply V-ph-Hz Control circuit supply 400-3-50 ± 10% kW 191/96 191/127 255/96 255/127 Nom. current draw** - circuits A + B/C A 251/125 251/167 334/125 334/167 Max. start-up current*** - circuits A + B/C A 535/371 535/426 645/371 645/426 * ** *** Power input, compressors and fans, at the unit operating limits (saturated suction temperature 10°C, saturated condensing temperature 65°C) and nominal voltage of 400 V (data given on the unit nameplate). Nom. unit current draw at standardised Eurovent conditions: evaporator entering/leaving water temperature 12°C/7°C, outside air temperature 35°C. Maximum instantaneous start-up current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor). Note: Units 30RB 602-802 have two electrical connection points. C A R R I E R 2 0 1 6 / 2 0 1 7 149 CONTROLS 24 V, via internal transformer Max. power input* - circuits A + B/C