AHI Carrier Catalog | Page 117

DUCTABLE AIR-COOLED LIQUID CHILLERS  30RBSY 039-160 Remote operating mode with dry contacts (standard) A simple two-wire communication bus between the RS485 port of the AquaSnap and the Carrier Comfort Network offers multiple remote control, monitoring and diagnostic possibilities. Carrier offers a vast choice of control products, specially designed to control, manage and supervise the operation of an air conditioning system. Please consult your Carrier representative for more information on these products. -- Start/stop: Opening of this contact will shut down the unit -- Dual set point: Closing of this contact activates a second set point (example: unoccupied mode) -- Water pump 1 and 2 control (contacts supplied with the hydronic module option)*: These outputs control the contactors of one or two water heat exchanger water pumps -- Alarm indication: this volt-free contact indicates the presence of a major fault that has led to the shut-down of one or two refrigerant circuits -- Demand limit 1 and 2: Losing of these contacts limits the maximum unit capacity to three predefined values -- User safety: This contact can be used for any custo mer safety loop, closing of the contact generates a specific alarm COOLING Carrier Comfort Network (CCN) operating mode Operating limits Operating range Minimum Maximum* Maximum dual pump** 30RBSY 30RBSY Low pressure*** High pressure*** Evaporator 7.5* 30 039 0.9 3.0 2.9 3.4 Leaving water temperature during operation °C 5** 20 045 0.9 3.4 3.2 3.8 Entering/leaving water temperature difference K 3 10 050 0.9 3.7 3.3 4.0 Condenser 060 0.9 4.2 3.7 4.4 Entering air temperature, full load*** °C -20 46 070 1.0 5.0 4.1 5.0 Entering air temperature, part load*** °C -20 48 080 1.2 5.5 4.4 5.2 Hydronic module**** 090 1.3 6.8 5.1 6.2 Entering air temperature 100 1.5 7.7 6.3 6.5 Kit without pump °C -20 - 120 1.7 8.5 6.5 8.0 Kit with pump (option 116x) °C -10 - 140 2.0 10.6 7.9 8.7 °C -20 - 160 2.3 11.2 8.2 8.9 Kit with pump (option 116x) and frost protection option to -20°C (option 42) * ** *** Maximum flow rate at a pressure drop of 100 kPa in the plate heat exchanger (unit without hydronic module). Maximum flow rate at an available pressure of 20 kPa (unit with low-pressure hydronic module) or 50 kPa (high-pressure module). Maximum flow rate with single pump is 2 to 4% higher, depending on the size. 55 Entering water temperature at start-up Minimum Maximum °C HEATING HEATING Flow rate, l/s Note: Do not exceed the maximum operating temperature. * ** For entering water temperatures below 7.5°C at start-up, contact Carrier. For low-temperature applications, where the leaving water temperature is below 5°C, a frost protection solution must be used. *** For transport and storage of the 30RBSY units the minimum and maximum allowable temperatures are -20°C and +48°C. It is recommended that these temperatures are used for transport by container. **** Defines the frost-free temperature of the hydronic components for use without glycol. 45 Outside air temperature, °C 35 25 15 5 -5 -15 30RBSY 0 5 10 15 20 CONTROLS -25 25 Evaporator leaving water temperature, °C Full load Minimum load Note: This operating range applies up top 130 Pa static pressure without suction air duct for sizes 070-080 and 140-160, and up to 240 Pa for all other sizes. C A AIR TREATMENT Evaporator water flow rate R R I E R 2 0 1 6 / 2 0 1 7 117